ATC Environmental, Inc.
104 East 25th Street
New York, New York 10010
ATC Associates Inc. Approved N.Y. State ELAP #10879
104 East 25th Street ACCREDITED NVLAP Lab Code #1187
New York, NY 10010 Report Date: 09/28/01
f-r, ASBESTOS FIBER TiNALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM)
with Fiber Identification by.Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS)
Method: AHERA Final Rule, EPA Federal Register (40 CFR, Part 703), Vol. 52, Ko. 210, October 30, 1987
r~i
Sample Identification Analysis Parameters
Project/Site: 40 Rector Street, NY, NY TEM Sample No.: 5574 - 59647
Floors 15-17
Date Received: 09/28/01 Grid Openings Analyzed:__ 6
Project Sample No. .•130 Average Grid Opening: IC 6.00 urn
Air Volume: 128Q liters Total Area Analyzed: 0.0674 mm2
' Filter Type: MCE 25 mm diam., Pore Size: 0.45 urn Analytical Sensitivity; 14.B s/mm2
, Effective Area': 385 mm2 ' 0.0045 s/cc
FIBROUS PARTICULATES ANALYZED
Number Observed CONCENTRATION
Total
Single Matrix Total. Struct. Filter Air
Fibers Bundles Clusters Struct. Struct >=5um Struct/mTn2 Struct/cc nqm/m3
0V Chrysotile Asbestos . 0 0 0 0 0 0 0.0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Ambiguous 0 0 0 0 0 0 0.0 0.0000 0
to
Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 c
Non~Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A
No Identification 0 0 0 0 0 0 0.0 0.0000 N/A
Totals (All Structures) 0 0 0.0 0.0000 N/A
The estimated uncertainty of this analysis is 1 standard deviation.
Non-asbestos fiber i.d, (EDS/SAED): None detected
; J Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method.
'0 This laboratory is in compliance with the quality specified for the method.
f 'I Analyzed by: Report Reviewed by:
Marek Peysakhov Michael A. Gorycki, Ph.D.
rT Director of Electron Microscopy
L_J