NYC 9/11 Public Portal Document
■ u
ATC Environmental, Inc.
r"\ 104 East 25th Street
New York, New York 10010
ATC Associates Inc. Approved N.Y. State ELAP #10879
I
104 East 25th Street ACCREDITED NVLAP Lab Code # 1187
New York, NY 10010 Report Date: 09/29/01
ASBESTOS FIBER TkNALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM)
With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS)
Method: AHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol, 52, No. 210, October 30, 1987
I Sarnple Identification Analysis Parameters
Project/Site: 40 Rector Street, NY/ NY TEM Sample No.: 5579 59751
Foors 6, 7, 3, 4, 11, 2, l/Lobby
Date Received:09/29201 Grid Openings Analyzed:__ 6
Project Sample No.: T28 Average Grid Opening: 106.00 um
Air Volume: 1280 liters Total Area Analyzed; 0.0674 mTn2
■—1
Filter Type: MCE 25 mm diam., PoreSizej^0^45um Analytical Sensitivity: 14.8 s/mm2
Effective Area: 365 mm2 0.0045 s/cc
FIBROUS PARTICULATES ANALYZED
Number Observed CONCENTRATION
Total
Single Matrix Total. struct. Filter Air
Fibers Bundles Clusters Struct. Struct. >=5um Struct/mm2 Struct/cc ngm/m3
Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Ambiguous 0 0 0 0 0 0 0.0 0.0000 . 0
Total asbestos {includes ambiguous structures) 0 0 0.0 0.0000 C
Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A
Ko Identification 0 0 0 0 0 0 0.0 0.0000 N/A
Totals (All Structures) 0 0 0.0 0..0O0O N/A
The estimated uncertainty of this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected
Amphibole Asbestos Type: None detected
I The Analysis was carried out in accordance with the approved TEM method.
This laboratory is in compliance with the quality specified for the method.
iJ
Analyzed by: Report Reviewed by:
Marek Peysakhov Michael A. Gorycki, Ph.D.
Director of Electron Microscopy
Lj
NYC-WTC_000237206