Client Name: TRC Environmental Corporation
Phase Contrast Microscopy (PCM) Fiber Results
35052-0000-00007; New York City Law Department; 100 Church Street / OSHA
Flow Air Fiber Fibers
SciLab Client Rate Duration Filtered Density Cone. TWA
Fields Fibers
Sample # Sample # / Location Collected ()iters/min.) (min.) (liters) (Fibers/mm^ ) (Fibers/cc)
01 GS-3/8/O2-STEL-O334 3/8/02 2 30 60 100 4 5.10 <0.045
Mike Green
02 GS-3/8/02-STEL-0335 3/8/02 2 60 120 100 2 2.55 . <0.022
Wilson Bueno
03 GS-3/8/02-STEL-0336 3/8/02 0 0 0 100 0.5 0.64
Blank Footnotes: /
04 GS-3/8/02-STEL-0337 3/8/02 0 0 0 100 0.5 0.64
Blank Footnotes: 7
Reporting Notes:
(1) Fibers/cc cannot be calculated ft (or blanks) with no air volume.
Analyzed by: Tatyana Grimchak Date Analyzed; 3/9/02
Samples analyzed by NIOSH 7400(A) IWetl(^J^^$3f'S7T5/94: Limit of Detections 5.5 fibers per 100 fields or 7 fibers/nun2: This report relates ONLY to the sample analysis expressed as fibers/sq mm of filler area: ND=No fibers observed: NA= Not
Analyzed; Walton-Beckett graticle field area = 0.00785 mm2: TWA = 8 Hr TWA calculation assumes zero exposure for remainder of 8 lir period not sampled; Upper 95% Confidence limit (Employers Compliance Test)- Calculated as a one sided UCL to
determine 95% certainty of compliance with the 0.01 fiber/cc standard; Estimated relative standard deviation: Intralab Sr=0.405, Interlab Sr=0,45, New York samples (NYSDOH ELAP Lab # 11480); National Institute of Standards and Technology
Accreditation requirements mandate that this report must not be reproduced except in full without the approval of the laboratory. AIHA # 102843.