Client Name: TRC Environmental Corporation
Phase Contrast Microscopy (PCM) Fiber Results
35052-0000-00004; NYC Law Dept.; 100 Church Street. (OSHA)
Flow Air Fiber Fibers
SciLab Client Rate Duration Filtered Density Cone.
Fields Fibers TWA
Sample # Sample # / Location Collected (liters/min.) (min.) (liters) (Fibers/mm^ ) (Fibers/cc)
01 GSl 01/26/2002 3 300 900 too 42 53.50 0.023
Wilfredo Ramirez 6th Floor
02 GS2 01/26/2002 3 330 990 100 9 11.46 0.004
Wilfredo Ramirez 6th Floor
03 GS3 01/26/2002 3 291 873 100 4 5.10 < 0.003
Daniel Reilly 3rd Floor
04 GS4 01/26/2002 3 330 990 100 29 36.94 0.014
Daniel Reilly 3rd Floor
05 GS5 01/26/2002 0 0 0 100 0.5 0.64
Blank Footnotes: 1
06 GS6 01/26/2002 0 0 0 100 0.5 0.64
Blank Footnotes: 1
Reporting Notes:
(1) Fibers/cc cannot be de: mMltlrnTrSTrvolLime.
Analyzed by: Anthony Hinton _ [Date Analyzed: 01/26/2002
Samples analyzed by NIOSH 7/ 1' Limit ^Detections 5.5 fibers per 100 fields or 7 fibers/mm2: This report relates ONLY to the sample analysis expressed as fibers/sq mm of filter area: ND=No fibers observed: NA= Not
Analyzed; Walton-Beckett graticle field area = 0.00785 mnl2: TwX = 8 Hr TWA calculation assumes zero exposure for remainder of 8 hr period not sampled; Upper 95% Confidence limit (Employers Compliance Test)- Calculated as a one sided UCL to
determine 95% certainty of compliance with the 0.01 fiber/cV standard: Estimated relative standard deviation: Intralab Sr=0.405, Interlab Sr=0.45, New York samples (NYSDOH ELAP Lab # 11480): National Institute of Standards and Technology
Accreditation requirements mandate that this report must not iWeproduced except in full without the approval of the laboratory. AIHA # 102843.