Sci .b#: 202032650 Pa of 1
Client Name: TRC Environmental Corporation
Phase Contrast Microscopy (PCM) Fiber Results
35052-0000-00007; New York City Law Department; 100 Church Street / AMBIENT
Flow Air Fiber Fibers
SciLab Client Rate Duration Filtered Density Cone.
Fields Fibers TWA
Sample # Sample # / Location Collected (liters/min.) (min.) (liters) (Fibers/mm^ ) (Fibers/cc)
01 GS-3/15/02-ASB-0201 3/15/02 5 240 1200 100 2 2.55 < 0.002
Room 2-170
02 GS-3/15/02-ASB-0202 3/15/02 5 240 1200 100 3 3.82 < 0.002
Room 2-173
03 GS-3/15/02-ASB-0203 3/15/02 5 300 1500 100 3 3.82 <0.002
Room 2-177
04 GS-3/15/02-ASB-0204 3/15/02 5 300 1500 100 5 6.37 < 0.002
Room 2-179
05 GS-3/15/02-ASB-0205 3/15/02 0 0 0 100 0.5 0.64
Blank Footnotes: /
06 GS-3/15/02-ASB-0206 3/15/02 0 0 0 100 0.5 0.64
Blank Footnotes: I
Reporting Notes:
(1) Fibers/cc cannot be calculi ilanks) with no air volume.
Analyzed by: Tatyana Grimchak_______ /■ Analyzed: 3/16/02
Samples analyzed by NIOSH 7400(A) Method, Issue 8/15/94: Limit of Detection= 5.5 fibers per 100 fields or 7 fibers/ram2: This report relates ONLY to the sample analysis expressed as fibers/sq mm of filter area: ND=No fibers observed: NA= Not
Analyzed; Walton-Beckett graticle field area = 0.00785 mm2: TWA = 8 Hr TWA calculation assumes zero exposure for remainder of 8 hr period not sampled: Upper 95% Confidence limit (Employers Compliance Test)- Calculated as a one sided UCL to
determine 95% certainty of compliance with the 0.01 fiber/cc standard: Estimated relative standard deviation; Intralab Sr=0.405. Interlab Sr=0.45, New York samples (NYSDOH ELAP Lab # 11480); National Institute of Standards and Technology
Accreditation requirements mandate that this report must not be reproduced except in full without the approval of the laboratory. AIHA # 102843.
NYC-WTC_000235535
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000235535Source: NYC Law Department, mirrored locally