Asbestos air fiber results, 100 Church Street, Oct 2001

Machine-extracted title · confidence 95%

Laboratory report documenting PCM microscopy fiber counts for ambient asbestos air samples collected at 100 Church Street.

NYC-WTC_000235232
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Sei; .b#: 202032650 Pa of 1 Client Name: TRC Environmental Corporation Phase Contrast Microscopy (PCM) Fiber Results 35052-0000-00007; New York City Law Department; 100 Church Street / AMBIENT Flow Air Fiber Fibers SciLab Client Rate Duration Filtered Density Cone. Fields Fibers TWA Sample # Sample # / Location Collected (Uters/min.) (min.) (liters) (Fibers/mm^ ) (Fibers/cc)

01 GS-3/15/02-ASB-0201 3/15/02 5 240 1200 100 2 2.55 < 0.002 Room 2-170 02 GS-3/15/02-ASB-0202 3/15/02 5 240 1200 100 3 3.82 <0.002 Room 2-173 03 GS-3/15/02-ASB-0203 3/15/02 5 300 1500 100 3 3.82 < 0.002 Room 2-177 04 GS-3/15/02-ASB-0204 3/15/02 5 300 1500 100 5 6.37 < 0.002 Room 2-179 05 GS-3/15/02-ASB-0205 3/15/02 0 0 0 100 0.5 0.64 Blank Footnotes: I 06 GS-3/15/O2-ASB-O2O6 3/15/02 0 0 0 100 0.5 0.64 Blank Footnotes: 1 Reporting Notes: (1) Fibers/cc cannot be calcul^cTw^ampte^iP-blanks) with no air volume. Analyzed by: Tatyana Grimchak________ // Analyzed: 3/16/02 Samples analyzed by NIOSH 74OO(A] Method. Issue #4 8/15/94: Limit of Detectioo= 5.5 fibers per 100 fields or 7 fibers/mm2: This report relates ONLY to the sample analysis expressed as fibets/sq nun of filter area: ND=No fibers observed: NA= Not Analyzed; Walton-Beckett graticle field area = 0.00785 mm2: TWA a 8 Hr TWA calculation assumes zero exposure for remainder of 8 hr period not sampled: Upper 95% Confidence limit (Employers Compliance Test)- Calculated as a one sided UCL to determine 95% certainty of compliance with the O.Ol fiber/cc standard: Estimated relative standard deviation: Intralab Sr=0.405, Interlab Sr=0.45, New York samples (NYSDOH ELAP Lab ft 11480): National Institute of Standards and Technology Accreditation requirements mandate that this report must not be reproduced except in full without the approval of the laboratory. AIHA # 102843.

o

NJ

S O o o I o to cn cn

O', cn

NYC-WTC_000235232

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000235232Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →