NYC 9/11 Public Portal Document
Sci|^rob #: 202031109 p 1 of 1
Client Name: TRC Environmental Corporation
Phase Contrast Microscopy (PCM) Fiber Results
35052-0000-00007; New York City Law Department; 100 Church Street/AMBIENT
Flow Air Fiber Fibers
SciLab Client Rate Duration Filtered Density Cone.
Fields Fibers TWA
Sample # Sample # / Location Collected (liters/min.) (min.) (liters) (Fibers/mm^ ) (Fibers/cc)
01 GS-2/28/02-ASB-0308 2/28/02 5 300 1500 100 2 2.55 < 0.002
Room 5-177
02 GS-2/28/02-ASB-0309 2/28/02 5 300 1500 100 7 8.92 0.002
Room 5-180
03 GS-2/28/02-ASB-0310 2/28/02 5 300 1500 100 4 5.10 < 0.002
WS 3-118
04 GS-2/28/02-ASB-0311 2/28/02 5 300 1500 100 2.5 3.18 < 0.002
WS 3-125
05 GS-2/28/02-ASB-B1 2/28/02 0 0 0 100 0.5 0.64
Blank Footnotes: 1
06 GS-2/28/02-ASB-B2 2/28/02 0 0 0 100 0.5 0.64
Blank Footnotes: 1
Reporting Notes:
(1) Fibers/cc cannot be Jr samples volume.
Analyzed by: Anthony Hinton _ L_rn___', iate Analyzed; 3/2/02
Samples analyzed by NIOSH ;A) Metftod, Issue #2, [5®<VLtinit orDetections 5.5 fibers per 100 fields or 7 fibers/mm2: This report relates ONLY to the sample analysis expressed as fibers/sq mm of filler area; ND=No fibers observed: NA= Not
Analyzed; Walton-Beckett graflcle field area = 0.00785 nd iSiWA = 8 Hr TWA calculation assumes zero exposure for remainder of 8 hr period not sampled: Upper 95% Confidence limit (Employers Compliance Test)- Calculated as a one sided UCL to
determine 95% certainty of compliance with the O.OI fiber) : stanomd: Estimated relative standard deviation; Intralab Sr=0.405, Interlab Sr=0.45, New York samples (NYSDOH ELAP Lab # 11480); National Institute of Standards and Technology
Accreditation requirements mandate that this report must n be rejfroduced except in full without the approval of the laboratory. AIHA # 102843.