PCM fiber results lab report, 100 Church Street, Feb 2002

Machine-extracted title · confidence 95%

Laboratory report detailing PCM microscopy fiber analysis results for air samples collected at 100 Church Street in February 2002.

NYC-WTC_000235497
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Sci Ob#: 202021884 P 1 of I Client Name: TRC Environmental Corporation Phase Contrast Microscopy (PCM) Fiber Results 35052-0000-00007; NYC Law Dept; 100 Church St./ Ambient Flow Air Fiber Fibers SciLab Client Rate Duration Filtered Density Cone. Fields Fibers TWA Sample # Sample # / Location Collected (liters/min.) (min.) (liters) (Fibers/mm'^ ) (Fibers/cc)

01 GS-AMD-2902-0501 2/9/02 5 120 600 too 3 3.82 < 0.004 5 th Floor/At WS-5-153 A 02 GS-AMD-2902-0502 2/9/02 5 120 600 100 1.5 1.91 < 0.004 5th Floor/At WS-5-147A 03 GS-AMD-2902-0503 2/9/02 5 150 750 100 4 5.10 < 0.004 5th Floor/At WS-5-157A 04 GS-AMD-2902-0504 2/9/02 5 150 750 100 2 2.55 < 0.004 5th Floor/At RM-5-161 05 GS-AMD-2902-0505 2/9/02 0 0 0 100 0.5 0.64 Field Blank Footnotes: / 06 GS-AMD-2902-0506 2/9/02 0 0 0 100 0.5 0.64 Field Blank Footnotes: 1 Reporting Notes: e /) / (1) Fibers/cc cannot be calculatOTl&fjiainplra rfk/ wiJh-rlSair volume. Analyzed by; Anthony Hinton_____ I I UX, /y (pate^alyzed: 2/10702 Samples analyzed by NIOSH 7400(A) Method, Issue #2, sA 5/94: Limit of Detections 5.5 fibers per 100 fields or 7 fibcrs/ram2: This report relates ONLY to the sample analysis expressed as fibers/sq mm of filter area: ND=No fibers observed: NA= Not Analyzed; Walton-Beckett graticle field area = 0.00785 inniX 'TWA = 8 Hr TWA calculation assumes zero exposure for remainder of 8 lir period not sampled: Upper 95% Confidence limit (Employers Compliance Test)- Calculated as a one sided UCL to determine 95% certainty of compliance with the 0.01 fiber/cc standard: Estimated relative standard deviation: Intralab Sr=O.4O5. Interlab Sr=0.45, New York samples (NYSDOH ELAP Lab # 11480): National Institute of Standards and Technology Accreditation requirements mandate that this report must not be reproduced except in full without the approval of the laboratory, AIBA # 102843,

NYC-WTC_000235497

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000235497Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →