Scil^ob #: 202021252 P 1 of . 1
Client Name: TRC Environmental Corporation
Phase Contrast Microscopy (PCM) Fiber Results
35052-0000-0004; NYC Law Dept.; 100 Church St./Ambient
Flow Air Fiber Fibers
SciLab Client Rate Duration Filtered Density Cone.
Fields Fibers TWA
Sample # Sample # / Location Collected (liters/min.) (min.) (liters) (Fibers/mm^ ) (Fibers/cc)
01 GS-5 2/4/02 5 300 1500 100 2 2.55 < 0.002
4th Floor At WS 4-1985
02 GS-6 2/4/02 5 300 1500 100 1 1.27 < 0.002
4th Floor At WS 4-202A
03 GS-7 2/4/02 5 300 1500 100 8 10.19 0.003
4th Floor At WS 4-134A
04 GS-8 2/4/02 5 300 1500 100 6 7.64 0.002
4th Floor At WS 4-141A
05 GS-9 2/4/02 0 0 0 100 0.5 0.64
Field Blank Footnotes: 7
06 GS-10 2/4/02 0 0 0 100 0.5 0.64
Field Blank Footnotes: 1
Reporting Notes:
(1) Fibers/cc cannot Jffi calculated samples (or blanks) with no air volume.
Analyzed by: Devin Ahyeee-_HjB«iT *• - rrP*aCC-Date Analyzed: 2/4Z02
Samples analyzed by NIOSH 7400(A) Method, Issue #2, 8/15/94; Limit of Detection= 5.5 fibers per 100 fields or 7 fibers/nunO; This report relates ONLY to the sample analysis expressed as fibers/sq mm of filter area; ND=No fibers observed; NA= Not
Analyzed; Walton-Beckett graticle field area = 0.00785 mm2: TWA = 8 Hr TWA calculation assumes zero exposure for remainder of 8 hr period not sampled: Upper 95% Confidence limit (Employers Compliance Test)- Calculated as a one sided UCL to
determine 95% certainty of compliance with the 0.01 fiber/cc standard: Estimated relative standard deviation: Intralab Sr=0.405. Interlab Sr=0.45, New York samples (NYSDOH ELAP Lab # 11480): National Institute of Standards and Technology
Accreditation requirements mandate that this report must not be reproduced except in full wiOiout the approval of the laboratory. AIHA # 102843.
NYC-WTC_000235493
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000235493Source: NYC Law Department, mirrored locally