Asbestos air monitoring results, 100 Church Street, Feb 2002

Machine-extracted title · confidence 95%

Laboratory report of PCM fiber analysis for an air sample collected at 100 Church Street on February 26, 2002.

NYC-WTC_000235511
Page image
Scanned page image, NYC-WTC_000235511
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Sci b#: 202023695 P 1 of i

Client Name: TRC Environmental Corporation Phase Contrast Microscopy (PCM) Fiber Results 35052-0000-00007; New York City Law Department; 100 Church St. Flow Air Fiber Fibers SciLab Client Rate Duration Filtered Density Cone. TWA Fields Fibers Sample # Sample # / Location Collected (litcrs/min.) (min.) (liters) (Fibers/mm'^ ) (Fibers/cc)

01 GS-2/26/02-ASB-0510 2/26/02 5 300 1500 100 3 3.82 <0.002 5th Floor Hallway East 02 GS-2/26/02-ASB-0511 2/26/02 5 300 1500 100 3 3.82 < 0.002 5 th Floor Hallway West 03 GS-2/26/02-ASB-0304 2/26/02 5 300 1500 100 4 5.10 < 0.002 WS 3-141 04 GS-2/26/02-ASB-0305 2/26/02 5 300 1500 100 2 2.55 < 0.002 WS 3-138 05 GS-2/26/02-ASB-B1 2/26/02 0 0 0 100 0.5 0.64 Blank Footnotes: I 06 GS-2/26/02-ASB-B2 2/26/02 0 0 0 100 0.5 0.64 Blank Footnotes: 1 Reporting Notes: (1) Fibers/cc cannot be calculated for sijtm^s (or blanks) with no air volume. Analyzed by: Fred Corirossi Date Analyzed: 2/26/02 Samples analyzed by NIOSH 74(X)(A) Metliod, Issue #2, 8/15/94; Limit of Dctection= 5.5 fibers per 100 fields or 7 fibers/mm2: Tliis report relates ONLY to the sample analysis expressed as fibers/sq nun of filter area: ND=No fibers observed: NA= Not Analyzed; Walton-Beckett graticle field area = 0.00785 mm?: TWA = 8 Hr TWA calculation assumes zero exposure for remainder of 8 lu period not sampled: Upper 95% Confidence limit (Employers Compliance Test)- Calculated as a one sided UCL to determine 95% certainty of compliance with the 0.01 fiber/cc standard: Estimated relative standard deviation; Intralab Sr=0.405. Interlab Sr=0.45, New York samples (NYSDOH ELAP Lab # 11480): National Institute of Standards and Technology Accreditation requirements mandate that this report must not be reproduced except in full without the approval of the iaboratoiy, AIHA # 102843.

NYC-WTC_00023551 1

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000235511Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →