Client Name: TRC Environmental Corporation
Phase Contrast Microscopy (PCM) Fiber Results
35052-0000-00007; New York City Law Department; 100 Church St.
Flow Air Fiber Fibers
SciLab Client Rate Duration Filtered Density Cone. TWA
Fields Fibers
Sample # Sample # / Location Collected (litcrs/min.) (min.) (liters) (Fibers/mm'^ ) (Fibers/cc)
01 GS-2/26/02-ASB-0510 2/26/02 5 300 1500 100 3 3.82 <0.002
5th Floor Hallway East
02 GS-2/26/02-ASB-0511 2/26/02 5 300 1500 100 3 3.82 < 0.002
5 th Floor Hallway West
03 GS-2/26/02-ASB-0304 2/26/02 5 300 1500 100 4 5.10 < 0.002
WS 3-141
04 GS-2/26/02-ASB-0305 2/26/02 5 300 1500 100 2 2.55 < 0.002
WS 3-138
05 GS-2/26/02-ASB-B1 2/26/02 0 0 0 100 0.5 0.64
Blank Footnotes: I
06 GS-2/26/02-ASB-B2 2/26/02 0 0 0 100 0.5 0.64
Blank Footnotes: 1
Reporting Notes:
(1) Fibers/cc cannot be calculated for sijtm^s (or blanks) with no air volume.
Analyzed by: Fred Corirossi Date Analyzed: 2/26/02
Samples analyzed by NIOSH 74(X)(A) Metliod, Issue #2, 8/15/94; Limit of Dctection= 5.5 fibers per 100 fields or 7 fibers/mm2: Tliis report relates ONLY to the sample analysis expressed as fibers/sq nun of filter area: ND=No fibers observed: NA= Not
Analyzed; Walton-Beckett graticle field area = 0.00785 mm?: TWA = 8 Hr TWA calculation assumes zero exposure for remainder of 8 lu period not sampled: Upper 95% Confidence limit (Employers Compliance Test)- Calculated as a one sided UCL to
determine 95% certainty of compliance with the 0.01 fiber/cc standard: Estimated relative standard deviation; Intralab Sr=0.405. Interlab Sr=0.45, New York samples (NYSDOH ELAP Lab # 11480): National Institute of Standards and Technology
Accreditation requirements mandate that this report must not be reproduced except in full without the approval of the iaboratoiy, AIHA # 102843.
NYC-WTC_00023551 1
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000235511Source: NYC Law Department, mirrored locally