NYC 9/11 Public Portal Document
SciLa^b#; 202023697 Pag of 1
Client N^e: TRC Environmental Corporation
Phase Contrast Microscopy (PCM) Fiber Results
35052-0000-00007; New York City Law Dept.; 100 Church St.
Flow Air Fiber Fibers
SciLab Client D®*® Rate Duration Filtered Density Cone. TWA
Fields Fibers
Sample # Sample # / Location Collected (liters/min.) (min.) (liters) (Fibers/mm^ ) (Fibers/cc)
01 GS-2/25/02-STEL-0622 2/25/02 2 30 60 too 3 3.82 <0.045
Kyle Jones
02 GS-2/25/02-STEL-0623 2/25/02 2 30 60 100 2 2.55 < 0.045
Anthony Lindsey
03. GS-2/25/02-STEL-0624 2/25/02 0 0 0 100 0.5 0.64
Blank Footnotes; 1
04 GS-2/25/02-STEL-0625 2/25/02 0 0 0 100 0.5 0.64
Blank Footnotes: 1
Reporting Notes;
(1) Fibers/cc cannot be ^Slfculat^ foLsarnjlTSs^OT blanks) with no air volume.
Analyzed by: Fred Corirossi C : Date Analyzed; 2/26/02
Samples analyzed by NIOSH 7400(A) Method, Issue #2, 8/15/94: Limit of Detections 5.5 fibers per 100 fields or 7 fibers/mni2: This report relates (ONLY to the sample analysis expressed as fibers/sq mm of filler area; ND=No fibers observed; NA= Not
Analyzed; Walton-Beckett graticle field area = 0.00785 mm2: TWA = 8 Hr TWA calculation assumes zero exposure for remainder of 8 hr period not sampled; Upper 95% Confidence limit (Employers Compliance Test)- Calculated as a one sided UCL to
determine 95% certainty of compliance with the 0.01 fiber/cc standard: Estimated relative standard deviation: Intralab Sr=0.405, Interlab Sr=0.45, New York samples (NYSDOH ELAP Lab # 11480): National Institute of Standards and Technology
Accreditation requirements mandate that this report must not be reproduced except in full without tlie approval of the laboratory. AIHA # 102843.
a
___k
o
e
o
cn
co
o
o
00
co
NYC-WTC_000235642
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000235642Source: NYC Law Department, mirrored locally