Client Name: TRC Environmental Corporation
Phase Contrast Microscopy (PCM) Fiber Results
35052-0000-00007; NYC Law Dept.; 100 Church Street (Ambient)
Flow Air Fiber Fibers
SciLab Client Rate Duration Filtered Density Cone.
Fields Fibers TWA
Sample # Sample # / Location Collected (liters/min.) (min.) (liters) (Fibers/mm^ ) (Fibers/cc)
01 GS-ASB-0409 2/7/02 5 360 1800 100 6 7.64 0.002
4th Floor At WS 4-191b
02 GS-ASB-0410 2/7/02 5 360 1800 100 4 5.10 < 0.001
4th Floor At WS 4-188b
03 GS-ASB-0411 2/7/02 5 180 900 100 4 5.10 < 0.003
4th Floor At WS4-191b
04 GS-ASB-0412 2/7/02 5 180 900 100 2 2.55 < 0.003
4th Floor At WS 4-188b
05 GS-ASB-0413 2/7/02 0 0 0 100 0.5 0.64
Blank Footnotes: 1
06 GS-ASB-0414 2/7/02 0 0 0 100 0.5 0.64
Blank Footnotes: /
Reporting Notes:
(1) Fibers/cc cannot be ^alculated .les ^wWj^ air volumi
Analyzed by; Anthony Hinton___________ 1______ Date Analyze<f,JiWl2
Samples analyzed by NIOSH 7400(A) Method, Issue #2, T5/94:)fcSmit of 5.5 fibers per 100 fields or 7 fibers/mm2: Tliis report relates ONLY to the sample analysis expressed as fibers/sq mm of filter area: ND=No fibers observed: NA= Not
Analyzed; Walton-Beckett graticle field area = 0.00785 n t TWA = 8 Hr TWA calculation assumes zero exposure for remainder of 8 hr period not sampled: Upper 95% Confidence limit (Employers Compliance Test)- Calculated as a one sided UCL to
determine 95% certainty of compliance with the 0.01 fibe /standard: Estimated relative standard deviation: Intralab St=0.405, Interlab Sr=0.45, New York samples (NYSDOH ELAP Lab # 11480): National Institute of Standards and Technology
Accreditation requirements mandate that this report must not be reproduced except in full without the approval of the laboratory. AIHA # 102843.
NYC-WTC_000235496
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000235496Source: NYC Law Department, mirrored locally