PCM fiber results lab report, 100 Church Street, Feb 5

Machine-extracted title · confidence 95%

Laboratory report presenting PCM microscopy fiber analysis results for ambient air samples collected at 100 Church Street on February 5, 2002.

NYC-WTC_000235494
Page image
Scanned page image, NYC-WTC_000235494
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document Sci^^ob#; 202021401 1 of 1

Client Name; TRC Environmental Corporation Phase Contrast Microscopy (PCM) Fiber Results 35052-0000-00007; NYC Law Dept.; 100 Church Street AMBIENT Flow Air Fiber Fibers SciLab Client Rate Duration Filtered Density Cone. Fields Fibers TWA Sample # Sample # / Location Collected (liters/min.) (min.) (liters) (Fibers/mm^ ) (Fibers/cc)

01 GS-5 2/5/02 5 360 1800 100 11 14.01 0.003 4th Floor At WS 4-19la 02 GS-6 2/5/02 5 360 1800 100 1.5 1.91 < 0.001 4th Floor At WS 4-188a 03 GS-7 2/5/02 5 360 1800 100 10 12.74 0.003 4th Floor At WS 4-11 la 04 GS-8 2/5/02 5 360 1800 100 4 5.10 < 0.001 4th Floor At WS 4-116a 05 GS-9 2/5/02 5 240 1200 100 12 15.29 0.005 4th Floor At WS 4-24la 06 GS-10 2/5/02 5 240 1200 100 9 11.46 0.004 4th Floor At WS 4-204b 07 GS-11 2/5/02 5 240 1200 100 6 7.64 0.002 4th Floor At WS 4-209a 08 GS-12 2/5/02 5 240 1200 100 7 8.92 0.003 4th Floor At WS 4-21% Reporting Notes; ^7 / / Analyzed by: Lance Tuckruskye —"^1 Z-rPate Analyzed: 2/6/02 Samples analyzed by NIOSH 7400(A) Method, Issue #2, 8/15/94: Linjt of DetecUon= 5.5 fibers per 100 fields or 7 fibers/nim2: This report relates ONLY to the sample analysis expressed as fibers/sq mm of filter area: ND=No fibers observed: NA=Not Analyzed; Walton-Beckett graticle field area = 0.00785 min2: TWA =% Hr TWA calculation assumes zero exposure for remainder of 8 hr period not sampled: Upper 95% Confidence limit (Employers Compliance Test)- Calculated as a one sided UCL to determine 95% certainty of compliance with the 0.01 fiber/cc standard: Estimated relative standard deviation: Intralab Sr=0.405, Interlab Sr=0.45, New York samples (NYSDOH ELAP Lab # 11480): National Institute of Standards and Technology Accreditation requirements mandate that this report must not be reproduced except in full without the approval of the laboratory. AMA # 102843.

NYC-WTC_000235494

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000235494Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →