ScitAb#: 202021665 Pa of 1
Clien^ame: TRC Environmental Corporation
Phase Contrast Microscopy (PCM) Fiber Results
35052-0000-00007; NYC Law Dept.; 100 Church Street (OSHA)
Flow Air Fiber Fibers
SciLab Client Rate Duration Filtered Density Cone.
Fields Fibers TWA
Sample # Sample # / Location Collected (liters/min.) (min.) (liters) (Fibers/mm^ ) (Fibers/cc)
01 GS020702OSST0405 2/7/02 2 30 60 100 6 7.64 0.049
Peter Grimaldi S.T.E.L.
02 GS020702OSST0406 2/7/02 2 30 60 100 5 6.37 < 0,045
Joshua Figueroa S.T.E.L.
03 GS020702OSST0407 2/7/02 0 0 0 100 0.5 0.64
Blank Footnotes: 1
04 GS020702OSST0408 2/7/02 0 0 0 100 0.5 0.64
Blank Footnotes: 1
Reporting Notes:
(1) Fibers/cc cannot be caJjmlated for samples (or blanks) with no air volume.
Analyzed by: Anthony Hinton ; Date Analyzed: 2/8/02
Samples analyzed by NIOSH 7400(A) Method, Issue #2, 8/15/94: Limit of Detectian= 5.5 fibers per lOO fields or 7 fibers/mm2: This report relates ONLY to the sample analysis expressed as fibers/sq mm of filter area: ND=No fibers observed: NA= Not
Analyzed; Walton-Beckett graticle field area = 0.00785 mm2: TWA = 8 Hr TWA calculation assumes zero exposure for remainder of 8 hr period not sampled: Upper 95% Confidence limit (Employers Compliance Test)- Calculated as a one sided UCL to
determine 95% certainty of compliance with the 0.01 fiber/cc standard: Estimated relative standard deviation: InU-alab Sr=0.405, Interlab Sr=0.45, New York samples (NYSDOH ELAP Lab # 11480): National Institute of Standards and Technology
Accreditation requirements mandate that this report must not be reproduced except in full without the approval of the laboratory. AIHA # 102843.