■A
Sci b#: 202022014 Pa of 1
Client Name: TRC Environmental Corporation
Phase Contrast Microscopy (PCM) Fiber Results
35052-0000-00007; NYC Law Dept; 100 Church St.
Flow Air Fiber Fibers
SciLab Client Rate Duration Filtered Density Cone.
Fields Fibers TWA
Sample # Sample # / Location Collected (liters/min.) (min.) (liters) (Fibers/mm^ ) (Fibers/cc)
01 GS-05HA-21102-0511 2/11/02 3 360 1080 100 21 26.75 0.010
Pedro Paulino
02 GS-05HA-21102-0512 2/11/02 3 360 1080 100 18 22.93 0.008
Anthony Linsey
03 GS-05HA-21102-0513 2/11/02 3 210 630 100 7 8.92 0.005
Pedro Paulino
04 GS-O5HA-21102-0514 2/11/02 3 210 630 100 4 5.10 < 0.004
Anthony Linsdey
05 GS-05HA-21102-0515 2/11/02 0 0 0 100 0.5 0.64
Field Blank Footnotes: J
06 GS-05HA-21102-0516 2/11/02 0 0 0 100 0.5 0.64
Field Blank Footnotes: /
Reporting Notes:
(1) Fibers/cc cannot be emulated for samples (or blanks) with no air volume.
Analyzed by: Fred Corirossi Date Analyzed: 2/11/02
Samples analyzed by NIOSH 7460(A) Method, Issuc'#2r 8/15/94: Limit of Detections 5.5 fibers per 100 fields or 7 fibers/mn2: This report relates ONLY to the sample analysis expressed as fibers/sq mm of filler area; ND=No fibers observed: NA= Not
Analyzed; Walton-Beckett gralicle field area = 0.00785 mni2: TWA = 8 Hr TWA calculation assumes zero exposure for remainder of 8 lir period not sampled: Upper 95% Confidence limit (Employers Compliance Test)- Calculated as a one sided UCL to
determine 95% certainty of compliance with the 0.01 fiber/cc standard: Estimated relative standard deviation: Intralab Sr=0.405, Interlab Sr=0.45, New York samples (NYSDOH ELAP Lab # 11480): National Institute of Standards and Technology
Accreditation requirements mandate that this report must not be reproduced except in full without the approval of the laboratory. AIHA # 102843.
Q
H
to
S
O
o
o
I
o
on
on
Ui
to
co
NYC-WTC_000235278
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000235278Source: NYC Law Department, mirrored locally