Scil^fc3b#: 202031961 Pa^l of 1
Clien^ame: TRC Environmental Corporation
Phase Contrast Microscopy (PCM) Fiber Results
35052-0000-00007; New York City Law Department; 100 Church Street / AMBIENT
Flow Air Fiber Fibers
SciLab Client Rate Duration Filtered Density Cone.
Fields Fibers TWA
Sample # Sample # / Location Collected (liters/min.) (min.) (liters) (Fibers/mm^ ) (Fibers/cc)
01 GS-3/8/02-ASB-0337 3/8/02 5 300 1500 100 6.5 8.28 0.002
Room 3-323A
02 GS-3/8/02-ASB-0338 3/8/02 5 300 1500 100 3 3.82 < 0.002
Room 3-323B
03 GS-3/8/02-ASB-0339 3/8/02 5 300 1500 100 15 19.11 0.005
Room 3-319
04 GS-3/8/02-ASB-034O 3/8/02 5 300 1500 100 8 10.19 0.003
Hallway Around Room 3-319
05 GS-3/8/02-ASB-0341 3/8/02 0 0 0 100 0.5 0.64
Blank Footnotes: 1
06 GS-3/8/02-ASB-0342 3/8/02 0 0 0 100 0.5 0.64
Blank Footnotes: I
Reporting Notes:
(1) Fibers/cc cannot be calculat^for iks) with no air volume.
Analyzed by: Tatyana Grimchak______ / •'I__________________ ; Date Analyzed: 3/9/02
Samples analyzed by NIOSH 7400(A) Method, Issue #2, 8/15/94: Limit of Detection= 5.5 fibers per 100 fields or 7 fibers/mm2: This report relates ONLY to the sample analysis expressed as fibers/sq mm of filter area: ND-No fibers observed: NA= Not
Analyzed; Walton-Beckett graticle field area = 0.00785 nun2: TWA = 8 Hr TWA calculation assumes zero exposure for remainder of 8 hr period not sampled: Upper 95% Confidence limit (Employers Compliance Test)- Calculated as a one sided UCL to
determine 95% certainty of compliance with the 0.01 fiber/cc standard; Estimated relative standard deviation: Intralab Sr=0.405. Interlab Sr=0.45, New York samples (NYSDOH ELAP Lab # 11480); National Institute of Standards and Technology
Accreditation requirements mandate that this report must not be reproduced except in full without tlie approval of the laboratory. AIHA # 102843.