Page image not rendered yet. The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text
OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Sci ob#; 202021884 P 1 of I
Client Name: TRC Environmental Corporation
Phase£onitiiast Miciioscogy(PCM)JFlber Results
35052-0000-00007; NYC Law Dept; 100 Church St./ Ambient
Flow Air Fiber Fibers
SciLab Client Date Rate Duration Filtered Density Cone. TWA
Fields Fibers
Sample # Sample # / Location Collected (liters/min.) (min.) (liters) (Fibers/mm^ ) (Fibers/cc)
01 GS-AMD-2902-0501 2/9/02 5 120 600 100 3 3.82 < 0.004
5th Floor/At WS-5-153A
02 GS-AMD-2902-0502 2/9/02 5 120 600 100 1.5 I.9I < 0.004
5th Floor/At WS-5-147A
03 GS-AMD-2902-0503 2/9/02 5 150 750 100 4 5.10 < 0.004
5thnoor/AtWS-5-157A
04 GS-AMD-2902-0504 2/9/02 5 150 750 100 2 2.55 < 0.004
Sth Floor/At RM-5-161
05 GS-AMD-2902-0505 2/9/02 0 0 0 100 0.5 0.64
Field Blank Footnotes: /
06 GS-AMD-2902-0506 _____ 2/9/02 0 0 0 100 0.5 0.64
Field Blank Footnotes: /
Reporting Notes: Z? ! /) /
(1) Fibers/cc cannot be calcuIateaj^y^rcC^ ...........
Analyzed by: Anthony Hinton JLloa^alyzed: 2/10/02
Samples analyzed by NIOSH 7400(A) Method, Issue #2, 5^4: Limit of Delection= 5.5 fibers per 100 fields or 7 fibers/raml: This report relates ONLY to the sample analysis expressed as fibers/sq mm of filter area: ND=No fibers observed; NA= Not
Analyzed; Walton-Beckett graticle field area = 0.00785 minSj ^TWA = 8 Hr TWA calculation assumes zero exposure for remainder of 8 lir period not sampled; Upper 95% Confidence limit (Employers Compliance Test)- Calculated as a one sided UCL to
determine 95% certainty of compliance with the 0.01 fiber/cc standard; Estimated relative standard deviation: Intralab Sr=0.405, Interlab Sr=0.45, New York samples (NYSDOH ELAP Lab# 11480): National Institute of Standards and Technology
Accreditation requirements mandate that this report must not be reproduced except in full without the approval of the laboratory. AEHA # 102843.
o