NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

PCM fiber analysis results, Law Department, Feb 2002

Machine-extracted title · confidence 95%

Laboratory report showing PCM fiber analysis data for air samples collected at the Law Department site in February 2002.

NYC-WTC_000235181
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document Sci b#: 202013401 V*.

Client Name: TRC Environmental Corporation Phase Contrast Microscopy (PCM) Fiber Results 35052-0000-0004; NYC Law Dept.; 100 Church Street/Ambient Flow Air Fiber Fibers SciLab Client Rate Duration Filtered Density Cone. TWA Fields Fibers Sample # Sample # / Location Collected (Uters/min.) (min.) (liters) (Fibers/mm ) (Fibers/cc)

01 GS7 1/28/02 5 360 1800 100 4 5.10 <0.001 6th Fl, Northeast Side Of Bldg 02 GS8 1/28/02 5 360 1800 100 16 20.38 0.004 6th Fl, Northwest Side Of Bldg 03 GS9 1/28/02 5 360 1800 100 8 10.19 0.002 3rd Fl, Northeast Side Of Bldg 04 GSIO 1/28/02 5 360 1800 100 12 15.29 0.003 3k1 FI, Northwest Side Of Bldg 05 GSll 1/28/02 5 300 1500 100 10 12.74 0.003 6th Fl, Northeast Side Of Bldg 06 GS12 1/28/02 5 300 1500 100 2 2.55 < 0.002 6th Fl, Northwest Side Of Bldg 07 GS13 1/28/02 5 300 1500 100 1 1.27 < 0.002 3rd Fl, Northeast Side Of Bldg 08 GS14 1/28/02 5 300 1500 NA 3rd Fl, Northwest Side Of Bldg Footnotes: 2 09 GS15 1/28/02 0 0 0 100 0.5 0.64 Field Blank Footnotes: / 10 GS16 1/28/02 0 0 0 100 0.5 0.64 Field Blank Footnotes: / Reporting Notes: (1) Fibers/cc cannot be calculated for samples (or blanks) with no air volume. (2) Analyst was unable to quantify fiber concentration because of overloading of particulate material on the filter. Analyzed by: Devin Ahyee Date Analyzed: 1/29/02 o Samples analyzed by N1O5H 7400(A) Method, Issue ^2, 8/15/94; Limit of DetecGon= 5.5 fibers per 100 fields or 7 fibers/nim2: This report relates ONLY to the sample analysis expressed as fibers/sq mm of filler area: ND=No fibers observed: NA= Not H Analyzed; Walton-Beckett graticle field area = 0.00785 nun2: TWA = 8 Hr TWA calculation assumes zero exposure for remainder of 8 hr period not sampled: Upper 95% Confidence limit (Employers Compliance Test)- Calculated as a one sided UCL to

u K determine 95% certainty of compliance with the 0.01 fiber/cc standard: Estimated relative standard deviation: Intralab Sr=0.405, Interlab Sr=0.45, New York samples (NYSDOH ELAP Lab # 11480): National Institute of Standards and Technology Accreditation requirements mandate tliat this report must not be reproduced except in full without the approval of the laboratory. AIHA # 102843.

S o 1^ ro CD CD

kO

NYC-WTC_000235181

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000235181Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →