WTC Indoor ir t tT|pling and Analytical Procedures Media Sampling Points Analytical Sampling Method Proposed Sampling Vulnerability/Practicality Analytical Method Proposed Parameters

Settled Carpets, fabric furniture Asbestos ASTM D 5755-95 This is a micro vacuuming method. Three collocated samples ASTM D 5755-95 Dust or drapery in areas of will be collected from each location. orous Soft activity (living rooms, surfaces family rooms) Lead ASTM E 1973-99 This is a micro vacuuming method. Three collocated samples SW-846 601 OB will be collected from each location.

Settled Horizontal surfaces of Asbestos ASTM D 6480-99 Wipe Samples ASTM D 6480-99 (wipe) Dust tables or counters and on-porou bare floors, ceilings and s Hard walls in areas of activity surfaces (living rooms, family Lead ASTM E 1728 Wipe Samples SW-846 601 OB rooms) Dioxins ASTM D 6661-01 Wipe Samples ASTM 6661-01 /SW-846 8290

PAHs ASTM D 6661-01 Wipe Samples ASTM 6661-01 /SW-846 8270C

Silica ASTM E 1 728- Wipe Samples NIOSH 7500 (XRD)

MMVF ASTM D 6480-99 Samples will be combined with the asbestos sampling. EMSL MSD.0300

ndoor Air Areas of known activity Asbestos NIOSH 7400 Air pump operated at 1 OL/min for 8 hours to achieve the PCM NIOSH 7400 followed by TEM AHERA (living rooms, family COPC wkgroup detection limits method. rooms) Lead NIOSH 7300 Air pump operated at 1 OL/min for 8 hours to achieve the SW-846 601 OB COPC wkgroup detection limits PAHs TBD Pending sample volume Pilot clean-up study only SW-846 8270 requirements and to account for breakthrough on the cassettes.

Dioxins TBD Pending sample volume Pilot clean-up study only. Availability of sample cassettes for SW-846 8290 requirements and to account for dioxins analysis is questionable. Apparently the supply is low. O breakthrough on the cassettes. H l"^ Silica NIOSH 7500 Air pump operated at 2.5L/min for 8 hours to achieve the NIOSH 7500 (XRD) COPC wkgroup detection limits S MMVF NIOSH 7400 Assumed that it behaves the same as asbestos, samples will be EMSL MSD.0300 o combined with the asbestos sampling. O O I OTE: All samples (cassettes and wipes) will be preweighed by the laboratory or supplier prior to sample collection. After sample collection and upon receipt of the samples by the laboratory, the o iboratory will weigh the sample wipe or cassette prior to performing the analysis This may change depending upon the avaiiabiiity of preweighed materiais. May coiiect samples for total dust. o CD Silica will be collected as a dust samples as is Lead. This was decided since pulverized silica would be particulate like and not fiber like os with asbestos and MMVF. (JI (JI (JI

NYC-WTC_000234722

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000234722Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →