ATTACHMENT 2 *w a w WTC Indoor Ail fi ailing and Analytical Procedures Analytical yledia Sampling Points Parameters Sampling Method Proposed Sampling Vulnerability/Practicality Analytical Method Proposed

This is a micro vacuuming method. Three collocated samples eHled Carpets, fabric furniture Asbestos ASTM D 5755-95 will be collected from each location. ASTM D 575S95 Dust or drapery in areas of OUS Soft activity (living rooms, This is a micro vacuuming method. Three collocated samples irfaces family rooms) Lead ASTME 1973-99 will be collected from each location. SW-846 6010B

Asbestos ASTM D 6480-99 Wipe Samples ASTM D 6480-99 (wipe)

Lead ASTME 1728 Wipe Samples SW-846 601 OB

Dioxins ASTM D 6661-01 Wipe Samples ASTM 6661-01/SW-846 8290 Horizontal surfaces of tables or counters and PAHs ASTM D 6661-01 Wipe Samples ASTM 6661-01/SW-846 8270C ettled Dust bare floors, ceilings ond n-porou walls in areas of activity Silica ASTME 1728** Wipe Samples NIOSH 7500 (XRD) 1 Hard (living rooms, family irfaces rooms) MMVF ASTM D 6480-99 Somples will be combined with the asbestos sampling. EMSL MSD.O30O Air pump operated at lOL/min for 8 hours to achieve the COPC PCM NIOSH 7400 followed by TEM AHER7 Asbestos NIOSH 7400 wkgroup detection limits method. Air pump operated at lOL/min for 8 hours to achieve the COPC Lead NIOSH 7300 wkgroup detection limits SW-846 601 OB TBD Pending sample volume requirements and to account for PAHs break through on the cassettes. Pilot clean-up study only SW-846 8270 o H TBD Pending sample volume requirements and to account for Pilot clean-up study only. Availability of sample cassettes for Dioxins break through on the cassettes. dioxins analysis is questionable. Apparently the supply is low. SW-846 8290 Air pump operated at 2.5L/min for 8 hours to achieve the Silica NIOSH 7500 COPC wkqroup detection limits NIOSH 7500 (XRD) o Areas of known activity o (living rooms, family Assumed that it behaves the same as asbestos, samples will be Io toor Ail rooms) MMVF NIOSH 7400 combined with the asbestos sampling. EMSL MSD.0300 o co TE: All samples (cassettes and wipes) will be preweighed by the laboratory or supplier prior to sample collection. After sample collection and upon receipt of the samples by the laboratory, the to oratory will weigh the sample wipe or cassette prior to performing the analysis. This may change depending upon the avaiigbllity of preweighed materials. May collect samples for total dust. ro

NYC-WTC_000195860

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000195860Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000178163

Contractual document outlining services to collect and analyze dust samples for hazardous substances in selected New York City buildings.

Similar indexed content

Compare copies and versions →