NYC 9/11 Public Portal Document
ATTACHMENT 2
*w a w
WTC Indoor Ail fi ailing and Analytical Procedures
Analytical
yledia Sampling Points Parameters Sampling Method Proposed Sampling Vulnerability/Practicality Analytical Method Proposed
This is a micro vacuuming method. Three collocated samples
eHled Carpets, fabric furniture
Asbestos ASTM D 5755-95 will be collected from each location. ASTM D 575S95
Dust or drapery in areas of
OUS Soft activity (living rooms, This is a micro vacuuming method. Three collocated samples
irfaces family rooms) Lead ASTME 1973-99 will be collected from each location. SW-846 6010B
Asbestos ASTM D 6480-99 Wipe Samples ASTM D 6480-99 (wipe)
Lead ASTME 1728 Wipe Samples SW-846 601 OB
Dioxins ASTM D 6661-01 Wipe Samples ASTM 6661-01/SW-846 8290
Horizontal surfaces of
tables or counters and PAHs ASTM D 6661-01 Wipe Samples ASTM 6661-01/SW-846 8270C
ettled
Dust bare floors, ceilings ond
n-porou walls in areas of activity Silica ASTME 1728** Wipe Samples NIOSH 7500 (XRD)
1 Hard (living rooms, family
irfaces rooms) MMVF ASTM D 6480-99 Somples will be combined with the asbestos sampling. EMSL MSD.O30O
Air pump operated at lOL/min for 8 hours to achieve the COPC PCM NIOSH 7400 followed by TEM AHER7
Asbestos NIOSH 7400 wkgroup detection limits method.
Air pump operated at lOL/min for 8 hours to achieve the COPC
Lead NIOSH 7300 wkgroup detection limits SW-846 601 OB
TBD Pending sample volume
requirements and to account for
PAHs break through on the cassettes. Pilot clean-up study only SW-846 8270
o
H TBD Pending sample volume
requirements and to account for Pilot clean-up study only. Availability of sample cassettes for
Dioxins break through on the cassettes. dioxins analysis is questionable. Apparently the supply is low. SW-846 8290
Air pump operated at 2.5L/min for 8 hours to achieve the
Silica NIOSH 7500 COPC wkqroup detection limits NIOSH 7500 (XRD)
o Areas of known activity
o (living rooms, family Assumed that it behaves the same as asbestos, samples will be
Io toor Ail rooms) MMVF NIOSH 7400 combined with the asbestos sampling. EMSL MSD.0300
o
co
TE: All samples (cassettes and wipes) will be preweighed by the laboratory or supplier prior to sample collection. After sample collection and upon receipt of the samples by the laboratory, the
to oratory will weigh the sample wipe or cassette prior to performing the analysis. This may change depending upon the avaiigbllity of preweighed materials. May collect samples for total dust.
ro
NYC-WTC_000195860
OCR can misread numbers and units. Confirm readings against the page image before using them.