Part II - Environmental Community Monitoring Plan 133-135 Greenwich & 21-23 Thames Streets Airtek Project 05-0701 - Rev 2 September 16, 2005
Footnote 1: Sampling duration and/or flow rates may be modified to provide optimum analyte loading for analysis based on results of ongoing analyses. Initial Sampling flow rates should be in accordance with rates prescribed in the sampling method.
Footnote 2: Organics will be sampled as provided below under “Notes on the Community Air Monitoring Table.”
Notes on Community Air Monitoring Table:
General: Blanks will be processed in accordance with the analytical methodologies and standard industry practice.
Asbestos:
Asbestos sample collection will be performed in accordance with NIOSH 7402, “Asbestos by TEM”. Asbestos analysis will be performed utilizing Transmission Electron Microscopy (“TEM”) analysis specified in 40 CFR Part 763, Asbestos Hazard Emergency Response Act, (“AHERA”), with the following modifications:
1. The sensitivity on TEM air samples will be less than 0.002 s/cc. 2. Both the length and width of all asbestos fibers will be recorded. 3. Confirmation by EDS and/or SAED will be performed for each fiber analyzed. 4. The mineralogy of the fibers will be noted and recorded.
Dust:
Airborne dust and particles at the Site will be monitored using real-time air monitoring instrumentation. Real-time air monitoring for PM-2.5 and PM-10 will be accomplished with direct reading particulate in air monitors. Data from Met One E-BAM Particle (Counters are to be data logged. At one location the Met One E-BAM Particle Counter data, will be compared against PM-2.5 results from PM-2.5 direct read results obtained using a Met One BAM 1020 monitor. At another location, the Met One E-BAM Particle Counter data will be compared against PM-IO results from PM-10 direct read results obtained using a Met One BAM 1020 monitor. This equipment will be operated for at least one week before the Abatement Phase begins. Prior to the commencement of the Abatement Phase, the EPA Region 2 office will be provided with the results comparing the data from the Met One E-BAM with the alternative instrument and the* proposal of a correction factor, if needed.
Respirable Dust/Crystalline Silica - Metals - Total Dust:
Respirable dust and crystalline silica sampling will be performed according to NIOSH Method 0600 protocol with analysis following NIOSH Method 7500 (XRD).
10
CITY_DEP_WORBY_CANNATA_SUBP_000087255
NYC-WTC_000232136
OCR can misread numbers and units. Confirm readings against the page image before using them.
Related records
Browse subjects →Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
Same-box records
26 shared non-person entities · 1 shared topics · similarity 0.947
machine-extracted · confidence unavailable · Check page ↗10 shared non-person entities · similarity 0.936
machine-extracted · confidence unavailable · Check page ↗Filed elsewhere
NYC-WTC_000095766
Part II of a permit application dated January 10, 2006 for air monitoring during remediation at 30 West Street.
24 shared non-person entities · 1 shared topics · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000096676
Part III of an air monitoring plan for remediation and deconstruction at 30 Warren Street in January 2006.
24 shared non-person entities · 1 shared topics · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000134132
US EPA Region 2 letter dated November 15, 2005, confirming completion of environmental review for abatement plans at 133-135 Greenwich Street.
38 shared non-person entities · similarity 0.951
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000134871
EPA Region 2 letter regarding revised environmental work plan submission for two buildings including asbestos, health, and safety assessment components.
38 shared non-person entities · similarity 0.937
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155430
Technical correspondence addressing asbestos air sampling methodology and pump flow rate specifications.
10 shared non-person entities · similarity 0.935
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000162890
Technical discussion regarding discrepancies in NIOSH method flow rates and requirements for large sample volumes at 114 Liberty Street.
10 shared non-person entities · similarity 0.935
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140626
Draft scope of work for WTC debris/dust residential cleanup program with compliance requirements and regulatory overview.
10 shared non-person entities · similarity 0.935
machine-extracted · confidence unavailable · Check page ↗11 shared non-person entities · similarity 0.934
machine-extracted · confidence unavailable · Check page ↗11 shared non-person entities · similarity 0.933
machine-extracted · confidence unavailable · Check page ↗More like this page
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000134132
US EPA Region 2 letter dated November 15, 2005, confirming completion of environmental review for abatement plans at 133-135 Greenwich Street.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000095766
Part II of a permit application dated January 10, 2006 for air monitoring during remediation at 30 West Street.
Similarity score 0.993 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000096676
Part III of an air monitoring plan for remediation and deconstruction at 30 Warren Street in January 2006.
Similarity score 0.992 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000134871
EPA Region 2 letter regarding revised environmental work plan submission for two buildings including asbestos, health, and safety assessment components.
Similarity score 0.991 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.972 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000162890
Technical discussion regarding discrepancies in NIOSH method flow rates and requirements for large sample volumes at 114 Liberty Street.
Similarity score 0.971 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Buildings in this record
Machine-extracted building matches; verify each source. Buildings, never households.
- 1 Trinity Place · 1 pages · confidence 0.15 · verify page 3
- 125 Greenwich Street · 1 pages · confidence 0.15 · verify page 4
- 133-135 Greenwich Street · 3 pages · confidence 0.15 · verify page 1
Others also read
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000095766
Part II of a permit application dated January 10, 2006 for air monitoring during remediation at 30 West Street.
Similar indexed content
NYC-WTC_000096676
Part III of an air monitoring plan for remediation and deconstruction at 30 Warren Street in January 2006.
Similar indexed content
Similar indexed content
NYC-WTC_000134132
US EPA Region 2 letter dated November 15, 2005, confirming completion of environmental review for abatement plans at 133-135 Greenwich Street.
Similar indexed content
Similar indexed content