NYC 9/11 Public Portal Document
EMSL Analytical, Inc.
107 Haddon Ave., Westmont, NJ OSlOg
EMSL
Order 10:040305286
Attn: Andrew/ M N. Khan Customer ID: JLCC50
JLC Environmental Consultants, Inc. Customer PO:
200 Park Ave South, Suite 1001 Date Received; ’ 04/05/03 12:23 AM
NewYork, NY 10003
Fax: 212-420-6092 EMSL Order: 040305286
Project; #03-2744/NYCDEP—114 Liberty ST EMSL Project ID:
Report Date: 04/14/03 Date Analyzed: 04/14/03
Silica, Crystalline Analysis Performed X-Ray Diffraction (XRD)
Modified MOSH Method 7500, Issue 3,1/15/98
I Respirable Dust Airborne Silica
Sample Sample Silica Silica % Analytical
Sample ID Identification Particle Volume Weight Cone, Weight Cone. Silica Sensitivity
ID (L) (<ng) (mg/m’) (mg) (mg/m’) (mg/m’)
MB13687-1 12THFLR SOUTH Quartz 408 <0.002 N/A <0.0045 <0.0110 N/A 0.0110
MB 13687-2 1ITH FLR DINING Quartz 408 <0.002 N/A 0.0090 0.0221 N/A 0,0110
MB13687-3 lOTH FLR DINING Quartz 408 0.601 1.4730 0.0080 0.0196 1.3 0,0110
MB13687-4 9TH FLR DINING Quartz 408 0.014 0.0343 0.0090 0.0221 64.3 0.0110
MD13697-5 8TII FLR DINING Quuilz. 408 <0.002 N/A <0.0045 <0.0110 N/A 0.0110
MB13687-6 7TH FLR DINING Quartz 408 0.010 0.0245 <0,0045 <0.0110 45.0 0.0110
MB13687-7 6TH FLR DINING Quartz 408 0.090 0.2206 <0.0045 <0.0110 5.0 0.0110
MB136g7.g STH FLR DINING Quarte 408 <0.002 N/A <0.0045 <0.0110 N/A 0,0110
4TH FLR
MB13687-9 KITCHEN Quartz 408 0.115 0.2819 <0.0045 <0.0110 3.9 0,0110
Disclaimer: The laboratory can only verily the concentration of silica on the filter and not the final concentration due to data
obtained by non-laboratory personnel. In the absence of a bulk dust sample, neither the specific forms of crystalline silica
nor the interfering species can be fully determined. Hence, the amount for each phase, if anticipated, will be analyzed based on
primary, secondary, and/or tenlary peak data with comparison to calibration curves ot known standards. It should be noted that air
samples are meant for only quantifying silica (or a mineral phase) which must first be identified from a bulk dust sample. “<”
means less than the stated value. The lowest reportable value is equivalent to the Analytical Sensitivity that is calculated from the
lowest reprnducihle amniint of specific mineral detectable by the instrument.
Anant Samndra, Ph.D,
Analyst Stephen Siegel, CIH-Iiab Manager
Or other approved signatory
AIHA Accredited - Laboratory ID 11100194
Pagel of 3
CITY_DEP_WORBY_CANNATA_SUBP_000085293
NYC-WTC_000232104
OCR can misread numbers and units. Confirm readings against the page image before using them.