FEB-19-02 0B:23 FROH-PACE ANALYTICAL Bl 2-607-6444 T-536 P.02/04 F-851
1700 Elm Street - Suite 200
Minneapolis, MN 5S414
we Analytical_______ __
8290 Analysis Results Method
Tel; 612-607-1700
Fax: 612- 607-6444
Client - ATC
Client’s Sample ID ATe-0122-234M-DX1
Lab Sample ID 103283651
Filename U20211A_05
Injected By CVS
Total Amount Extracted 1 m2 Matrix WIPE
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 01/22/2002
ICAL Date 01/25/2002 Received 01/24/2002
CCal Filenam0(s) U20211 A_01 & U20211 A_15 Extracted 02/06/2002
Method Blank ID BLANK-1453 Analyzed 02/11/2002 15:40
Native Cone EMPC LRU Internal ng's Percent
Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2,3.7,8-TCDF ---- 0,0062 0.00200 I 2,3,7,B-TGDF-13G 2.00 84
Total TCDF 0.160 0.00200 2.3,7,8-TCDD-13C 2.00 73
1,2,3,7,8-P©CDF-13C 2.00 72
2,3,7,8-TCDD ND 0.00200 2,3.4,7,8-PeCDF-13C 2.00 71
Total TCDD 0.190 0.00200 1,2,3.7,8-PeCDD-13C 2.00 79
1,2.3,4,7,8-HxCDF.13C 2.00 103
1.2,3.7,8-PeCDF ND 0.01000 1,2,3,6.7.8-HxCDF-13C 2.00 87
2,3,4,7,8-P6CDF 0.0130 0.01000 I 2,3,4,6.7,8-HxCDF-13C 2.00 88
Total PeCDF 0.120 0.01000 1,2.3,7,8,9-HxCDF-13C 2.00 88
1,2,3,4,7,B-l-lxCDD-l3C 2.00 102
1,2,3,7.8-PeCDD ND 0.01000 1,2,3,6,7,8-HxCDD-13C 2.00 76
Total PeCDD 0.250 0.01000 1,2,3,4.6.7,8-HpCDF-13C 2.00 79
1.2,3.4,7,8.9-HpCDF-13G 2.00 72
1,2,3,4,7,8-HxCDF 0.0140 0.01000 I 1,2,3,4,6.7,8-HpCDD-13C 2.00 70
1,2,3,6.7,8-HxCDF ND 0.01000 OCDD-13C 4.00 64
2,3,4,6,7,8-HxCDF 0.015 - 0.01000 J
1,2,3,7,8.9.HxCDF ND - 0.01000 1.2,3.4-TCDD-13C 2.00 NA
Total HxCDF 0.065 0.01000 1,2,3,7,8.9-HxCDD-13C 2.00 NA
1.2,3,4,7,8-HxCDD ND 0.01000 2.3,7,8-TCDD-37Cl4 0.20 74
1,2,3,6,7,8-HxCDD 0.017 0,01000 J
1.2,3,7,8,9-HxCDD 0.013 0.01000 J
Total HxCDD 0.610 0.01000
1,2,3.4,6,7.8-HpCDF 0.034 0.01000 J Total 2,3,7,8-TCDD
1.2,3,4,7.8.9-HpCDF ND 0,01000 Equivalence: 0.0053 ng/m2
Total HpCDF - 0.054 0.01000 J (Using ITE Factors)
1,2,3,4.6,7,8-HpCDD 0.047 0.01000 J
Total HpCDD 0.093 0.01000 J
OCDF ND 0.02000
OCDD - 0,085 0.02000 EiJ
URL “ Lower Reporting Limit ;
Cone = Concentration (Totals include 2,3,7,8-substituted isomers) I = Interference
EMPC = Estimated Maximum Possible Concentration E = PCDE Interference
A s Detection Limit based on slgnal-to-noise measurement S = Saturated signal
J = Concentration detected is below the calibration range ND = Not Delected
B = Less than 10 times higher than method blank level NA Not Applicable
P = Recovery outside ot target range NC = Not Calculated
Nn = value obtained from additional analysis ’ = See Discussion
Report No.... 02-1053389
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent ot Pacs Analytical Services, Inc.
CITY_21MC100_002891163
NYC-WTC_000223535