NYC 9/11 Public Portal Document
Minneapolis, mn
weAnaIvticar_________ Method B290 Analysis Results
Tel: 612-607-1700
Fax- 612- 607-6444
Client - ATC
Client's Sample ID ATC-0222-234M-DX1
Lab Sample ID 103343364
Filename U20312A_20
Injected By CVS
Total Amount Extracted 1 m2 Matrix WIPE
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 02/22/2002
ICAL Date 03/12/2002 Received 02/25/2002
CCal Filename(s) U20312A_06 & U20312A_21 Extracted 03/05/2002
Method Blank ID BLANK-1499 Analyzed 03/13/2002 01:54
Native Cone EMPC LRL internal ng'S Percent
isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2,3,7,8-TCDF ND 0.0030 A 2,3,7,8-TCDF-13C 2.00 63
Total TCDF 0.020 0.0020 2,3,7,8-TCDD-13C 2.00 67
1,2,3,7,8-PeCDF-13C 2.00 60
2,3.7,8-TCDD ND 0.0059 A 2,3,4,7,8-PeCDF-13C 2.00 61
Total TCDD 0,016 0.0020 1,2,3.7,8-PeCDD-13C 2.00 67 *
1,2,3,4,7,8-HxCDF-13C 2.00 86
1,2,3,7,8-PeCDF ND 0.0100 1,2,3,6,7,8-HxCDF-13C 2.00 51
2,3,4.7,8-PeCDF ND 0.0100 2,3,4,6,7,8-HxCDF-13C 2.00 61
Total PeCDF ND 0.0100 1,2,3,7,8,9-HxCDF-13C 2.00 53
1.2.3,4,7,8-HxCDD-13C 2.00 102
1,2,3,7,8-PeCDD ND 0.0100 1,2.3,6,7,8-HxCDD-13C 2.00 63
Total PeCDD ND 0.0100 1,2.3,4,6,7,8-HpCDF-13C 2.00 65
1,2,3.4,7,8,9-HpCDF-13C 2.00 59
1,2,3,4,7,8-HxCDF ND 0.0100 1,2,3,4,6,7,8-HpCDD-13C 2.00 59
1,2,3,6.7,8-HxCDF ND 0.0100 OCDD-13C 4.00 51
2,3,4,6,7,8-HxCDF ND 0.0100
1,2,3,7,8,9-HxCDF ND 0.0100 1.2,3,4-TCDD-13C 2.00 NA
Total HxCDF ND 0.0100 1,2,3,7,8,9-HxCDD-13C 2.00 NA
1,2,3,4.7,8-HxCD{3 ND 0.0100 2,3,7,a-TCDD-37CI4 0.20 68
1,2,3,6,7,8-HxCDD ND 0.0100
1,2,3,7,8.9-HxCDD ND 0.0100
Total HxCDD 0.023 0.0100 J
1,2,3,4,6,7,8-HpCDF ND 0.0100 Total 2,3,7,8-TCDD
1,2,3,4,7,8,9-HpCDF ND 0.0100 Equivalence: 0.00029 ng/m2
Total HpCDF ND 0.0100 (Using ITE Factors)
1,2,3,4,6,7,8-HpCDD ---- 0.020 0.0100 I
Total HpCDD 0.019 ---- 0.0100 J
OCDF ND 0.0200
OCDD 0.290 0.0200
LHL = Lower Reporting Limit
Cone « Concentration (Totals include 2,3,7,8-sub8tituted isomers) I = Interference
EM PC 3 Estimated Maximum Possible Concentration E ■ PCDE Interference
A = Detection Limit based on signai-to-noise measurement S = Saturated signal
J = Concentration detected is below the calibration range ND = Not Detected
B a Less than 10 times higher than method blank level NA = Not Applicable
P s Recovery outside of target range NC = Not Calculated
Nn = Value obtained from additional analysis * s See Discussion
Report No.... 02-1054414
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc.
CITY_21MC100_002879178
NYC-WTC_000218502
OCR can misread numbers and units. Confirm readings against the page image before using them.