NYC 9/11 Public Portal Document 06/14/2002 00:14 FAX 2129434641 @04 J'

ambient group me ki <1 '•fall 1 indoor envirortinencai quality wr*ayi Un, LOOK wjier if*»unent conjvllins •JIA S. W Sl'iMk UX.I1S AsbciEM a field ttrvtcci TM UU, Hejblitory compKjnce pfogrirtt JaX .'i;. 46,-y»y- Air. wiser a sail aneiylieel laberktanes WIU aMllt-KTCHAHVieM

October IO, 2001

Mrs. Teresa Elman The Otto Gerdau Co. 80 Wall Street, PH. New York, NY. .10005

'Re: 80-82 Wall Street Ambient Project #211366

Dear Mrs. Elman The following is a summary of the indoor environmental quality survey that Ambient Group, Inc performed on September 18*. 2001 at the above referenced location The survey included sampling for airborne and settled dust characterization, as well as air monitoring for TEM analysis

Four (4) air samples were collected from various locations on the 12*. 8*, 4* and 2"^ floors and analyzed by transmission electron microscopy (TEM) for asbestos structures. The results of the analysis indicated that airborne asbestos levels at the time of testing were less than the analytical sensitivity of the instrument, as well as well below the EPA standard of 70 strjcturcs^mm^ and other recommended industry guidelines and/or regulations

Four (4) settled dust and four (4) air samples were collected for characterization analysis from various locations on the 12^, 8*, 4* and 2"^ floors. The samples were composed primarily of carbon particles, cement and/or gravel road dust. No asbestos was detected in the eight (8) samples collected. Many of these elements identified in the samples are commonly found in an indoor environment and should not pose any adverse health concerns to the building occupants.

It should be noted that skin fragments, which were also identified in the samples, consist primarily of dead epithelial cells which are constantly shed by humans and are present as a result of the building occupants. Likewise, decayed organic matter typically includes decaying plant material and food particles, and it is not uncommon to find these materials in samples collected from within commercial office buildings-

Anached please find copies of the laboratory reports for further details. Should you have any questions regarding this information, please feel fire to call me.

Sincerely, / Signed for Ambient Grqj4lnnc. by:

William Esposito, CIH President

k.lis un’i. \\ MIAMI H L HU AGO. I 1115 S6u-ClP! [12 7'4 -■'•1

CITY_21MC100_002388397

NYC-WTC_000220418

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000220418Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →