NYC 9/11 Public Portal Document
ambient group Inc. \.~I Ir1N 11 Hl \ngl'iRl i u.
Indoor environmental quality survayr, 31 WP.Fr 19,,, STRN.E-r
,1a, Pt.00R
water treatment consulting
14t1W YORX, NI;'W YORK toorA
Asbestos & lead Held services
TL: (L13f 463-7811
Regulatory compliance programs
PAx: (111) 463-9397
Air, water 4 salt analytical laboratories
WEB: WWWAManiNTGROUP.COM
October 3,
Mr. Brian cCann
Cushman & Wakefield a/a/f
J.P. Morgan (Chase Manhattan Bank
One Chase Manhattan Plaza
New York, New York 10081
Re: 15 Broad Street
Ambient Project #211352
Dear Mr. MgCann:
The following is a summary of the indoor environmental quality survey that Ambient Group, Inc.
performed on September 16th, 2001 at the above referenced location. The survey included
sampling for potable water, airborne and settled dust characterization, as well as asbestos
absence/presence in settled dust.
Three (3) setitled dust characterization samples were collected from various locations on floors 24,
12 and 2. The samples were composed primarily of cellulose, carbon particles, fiber glass and
gravel road dust. No asbestos was detected in any of the samples collected. Many of these
elements identified in the samples are commonly found in an indoor environment and should not
pose any adverse health concerns to the building occupants.
Five (5) air samples were collected from various locations on the 24s', 12d`, 2nd, 1"' and ground
floors and analyzed for dust characterization. The samples were composed primarily of carbon
particles, skin flakes, gravel road dust, and fungal spores. Many of these elements identified are
commonly found in the indoor air and should not pose any adverse health concerns. A trace
amount of asbestos was detected in the sample collected in the property management offices, the
level found i! well below any regulatory limits or guidelines.
It should be doted that skin fragments, which were also identified in the samples, consist primarily
of dead epithelial cells which are constantly shed by humans and are present as a result of the
building occupants. Likewise, decayed organic matter typically includes decaying plant material
and food particles, and it is not uncommon to find these materials in samples collected from
within commercial office buildings.
In addition to the settled dust samples, testing for carbon dioxide, carbon monoxide, volatile
organic compounds and airborne particulates was also performed. Airborne levels for each of
these param ters were within published guidelines/regulations.
Analysis of he two (2) water samples, collected from the locations noted below, indicated that all
measured parameters were within acceptable levels as defined by the Safe Drinking Water Act.
GLEN COVE, NY MIAMI. PL CHICAGO, 1L OrtANOE, CA
516 6o9-0009 log S6a-oror f11 517-1116 714 z8a-&5a5
091—d 9l0/ta00'd 09t-1 test 99Z 211 t 1N313DYNYlM 9N101111e—mold WdVV: t0 Z00Z-9Z—qed
NYC-WTC 000105340