NYC 9/11 Public Portal Document DETAILED BUILDING EVALUATION SAFETY ASSESSMENT FORM 16-140 Page 2 Sketch (optional) Provide a sketch of the building or damaged portions. Indicate damage points Estimated Building Damage If requested by the jurisdiction, estimate building damage (repair cost / replacement cost, excluding contents). U None : 3WEC WINTER SAROEN (COMLAPSEÓ) Broken Glass §Debris-All levels. Severe Struct. -mse Cecnerbay camard Ledis 17-26. collapsed to 10t4Flr (eset back) PLAN RATING If there is an existing rating from a previous evaluation, check the appropriate box. • RESTRICTED - Stuctural L UNSAFE -- Structural Previous rating: LIJ INSPECTED • RESTRICTED -- Collateral • UNSAFE - Collateral Inspector ID Date If necessary, revise the rating based on the new evaluation and team judgement. SEVERE conditions endangering the overall building are grounds for an UNSAFE rating. Local SEVERE and overall MODERATE conditions may allow a RESTRICTED USE rating. Indicate the current rating below and at the top of page one. • RESTRICTED USE - Structural INSPECTED 7 RESTRICTED USE -- Collateral UNSAFE - Collateral Record any use and entry restrictions: O Bldg 1s unsate @ SE Corner. Restrict all access two column bays trom perim wall ESE Corner, Esaa All Levels. © Bidg egerim access to Winter Garden 1s restricted. 3 Eastern FURTHER ACTIONS Bay of bldy has broken glass of debris. Requires Frang betone access Check boxes below only if further actions are needed. Barricades needed in the following areas: Protection for workers/ people at grade song East face. Keep away from SE Comner Detailed Evaluation recommended:LStructural L Geotechnical / • Other: ] Other recommendations: * Remore SE Corner remaining slabswhere hangung on. Evaluate capacity of remaining perimetes beam fo be repaired. CITY_21MC100_002833738 NYC-WTC_000220224

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000220224Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000166000 · Box 7FDNY

Official violation order document issued by the FDNY Bureau of Fire Prevention directing correction of safety violations at a premises.

Similar indexed content

Compare copies and versions →