5 shared non-person entities · 1 shared topics · similarity 0.951
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000209427
Label derived from the City's folder field. The City does not supply document titles.NYC-WTC_000209427–000209449
OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Even if Region 1 did not want to use this publi shed data on typical dust levels, it had it own data, developed during the testing of the Brookfield schools, that showed that clean surfaces and clean schools had much, much lower background dust levels.
Re*calculation of Region 1 dust benchmark with more appropriate values
Table 4 gives re-calculated values for dust benchmarks using more appropriate, accurate, and defensible values for ambient background air emd K-factors. A range of different calculations is given, showing tae effect of substituting several different values. In all cases, the result is a much lower dust benchmark than the one contrived by Region 1.
Brookfield School System and community rejection of EPA Region 1 benchmark of 45,000 s/cm^ for dust
The Brookfield School System in Connecticut and the community has rejected EPA Region I's benchmark for dust of 45,000 s/cm^ as not being well founded or protective. It has been tentatively decidi^d that a level of 5000 s/cm^ is the cleanup goal.” Because data clearly demonstrate that a cleaned surface, even in an asbestos-contaminated building, will only have 86 to 320 s/cnr asbestos (see Table 2) there is no reason why the cleanup standard should not be much lower.
As a brief history of the problem, recently teachers at the Huckleberry Hill elementary school in Brookfield, Connecticut were concerned with an asbestos abatement in the year 2000 where the Region 1 benchmark of 45,000 s/cm^ was the standard. The teachers hired an independent industrial hygienist. Side-by-side testing was performed with the school system’s testing consultant. High, levels of asbestos were found by the ASTM 5755 microvacuum method in two carpets (over 462,240 and 329,560 s/cm^) as well as on top of a fire alarm box (over 3 million s/cm^) and on bare floors in another corridor (around 150,000 s/cm^).^’
The students were to be transferred to a middle; school to finish the year, but this school was tested and also found to have high asbestos dust levels, and failed the AHERA air test. At another school, asbestos was found in surface dusts at concentrations as high as 14 million s/cm\ The whole schoo l system was then shut down for the rest of the school year for further testing and inspection.^’
- 16-
CITY_21MC100_002847472
NYC-WTC_000209442
OCR can misread numbers and units. Confirm readings against the page image before using them.
Related records
Browse subjects →Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
Same-box records
Filed elsewhere
NYC-WTC_000140040
Technical memorandum from EPA discussing ultrasonication testing for asbestos in carpets and HEPA vacuuming effectiveness.
15 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140083
Forwarded EPA memorandum dated June 9, 2002, concerning the Asbestos Reservoir and carpet testing methods.
15 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140138
EPA memorandum addressing World Trade Center asbestos contamination status and agency efforts to provide information on the situation.
13 shared non-person entities · 1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140170
EPA memorandum on wipe sampling methods for asbestos in Lower Manhattan buildings, resuspension projections, and cancer risk estimates from WTC dust exposure.
13 shared non-person entities · 1 shared topics · similarity 0.983
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140127
Technical memorandum from EPA discussing ultrasonication testing for asbestos in carpets and HEPA vacuuming effectiveness.
10 shared non-person entities · 1 shared topics · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000151635
EPA memorandum detailing plans for asbestos wipe sampling, projecting airborne dust levels, and estimating increased cancer risks from WTC dust exposure.
11 shared non-person entities · 1 shared topics · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140259
Memorandum detailing procedures for asbestos wipe sampling in Lower Manhattan and estimating associated cancer risks from dust exposure.
11 shared non-person entities · 1 shared topics · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000154652
Internal tracking document for managing reports, comments, and actions related to environmental compliance cases.
11 shared non-person entities · 1 shared topics · similarity 0.977
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140235
Memorandum comparing asbestos data in Manhattan to other sites and arguing for cleanup under the Superfund statute.
11 shared non-person entities · 1 shared topics · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000125845
Draft fact sheet from DOH and DEP addressing tenant concerns regarding asbestos fibers at 105 Duane Street.
11 shared non-person entities · 1 shared topics · similarity 0.960
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000094469
Letter from Enviroscience Consultants providing air and bulk sampling results for 86 Trinity Place.
5 shared non-person entities · 1 shared topics · similarity 0.952
machine-extracted · confidence unavailable · Check page ↗More like this page
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000140083
Forwarded EPA memorandum dated June 9, 2002, concerning the Asbestos Reservoir and carpet testing methods.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140040
Technical memorandum from EPA discussing ultrasonication testing for asbestos in carpets and HEPA vacuuming effectiveness.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140138
EPA memorandum addressing World Trade Center asbestos contamination status and agency efforts to provide information on the situation.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140040
Technical memorandum from EPA discussing ultrasonication testing for asbestos in carpets and HEPA vacuuming effectiveness.
Similarity score 0.971 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140138
EPA memorandum addressing World Trade Center asbestos contamination status and agency efforts to provide information on the situation.
Similarity score 0.970 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140083
Forwarded EPA memorandum dated June 9, 2002, concerning the Asbestos Reservoir and carpet testing methods.
Similarity score 0.970 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Others also read
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000140040
Technical memorandum from EPA discussing ultrasonication testing for asbestos in carpets and HEPA vacuuming effectiveness.
Similar indexed content
NYC-WTC_000140083
Forwarded EPA memorandum dated June 9, 2002, concerning the Asbestos Reservoir and carpet testing methods.
Similar indexed content
NYC-WTC_000140138
EPA memorandum addressing World Trade Center asbestos contamination status and agency efforts to provide information on the situation.
Similar indexed content
NYC-WTC_000140170
EPA memorandum on wipe sampling methods for asbestos in Lower Manhattan buildings, resuspension projections, and cancer risk estimates from WTC dust exposure.
Similar indexed content
NYC-WTC_000140127
Technical memorandum from EPA discussing ultrasonication testing for asbestos in carpets and HEPA vacuuming effectiveness.
Similar indexed content