REGION 1's BENCHMARK FOR SETTLED ASBESTOS DUST

EPA Region 1 derived a benchmark, or a safe level, for asbestos in settled dust in order to justify asbestos levels found in the Brookfield, Connecticut school system.^* A level of 45,000 structures asbestos per square centimeters (s/cm^) was derived as the benchmark. This is remarkably high considering the universally accepted level of 1000 s/cm^ as low. (See Table 2.)

As discussed later, the Brookfield School System has roundly rejected EPA Region I's unsafe level of45,000 s/cm^ asbestos dust, and has instead chosen a tentative cleanup level of5000 s/cm^ for the schools to be occupied by its children.

Description of Region 2's risk assessment for settled asbestos dust: Use of a “K-factor” to back-calculate dust levels from background air levels

EPA Region 1 calculated its benchmark by first assigning a level for background ambient outside air. Then, it used a stud/’ which found different ratios between the amount of dust on surfaces with the amount of asbestos in the air, depending on the activities going on in a room that would stir up dusts. The ratios of dust levels to air levels are called “K-factors.”

For its calculations, Region 1 assigned a false value of 0.045 structures per milliliter (s/mL) as the supposed background ambient outside air level. Then, then chose an incorrect K-factor of 0.000001 (which is the same as 10"* if expressed as an exponential) as the ratio between air levels and dusts. The result was 45,000 structures per square centimeter (s/cm^) dust on surfaces, using the following formula.

Benchmark for x K-Factor [K-Factor Air Level, structures per milliliter asbestos in expressed (s/mL) Dust, structures as per square exponential

45,000 X 0.000001 [ 10 (-6) ] 0.045 This is the level This is the K-factor, or multiplier, This is the alleged background outdoor air derived from the chosen by Region 1 level put into the formula by Region 1. This formula by Region 1 value is the one highest outlier measurement found in an early 1983 study.

-12-

NYC-WTC_000140148

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000140148Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000121065 · Box DEP Box 48

Summary of air and dust sampling results collected from private residences and common areas at 250 South End Avenue.

Cited alongside this record in an Ask answer

Compare copies and versions →