Table 4. RE-CALCULATION OF REGION 1 DUST BENCHMARKS USING MORE VALID VALUES
FORMULA USED BY REGION 1:
Benchmark for X K-Factor (K-Factor Air Level, structures per asbestos in Dusi: expressed as an milliliter (s/mL) (s/cm2) exponential)
45,000 X 0.000001 ( 10-®) 0.045 This is the level derived from the This is the K-factor chesen by Region 1 for their This is the alleged background outdoor formula by Region 1 calculations, from the 2 highest ones from a total of six K- air level put into the formula by Region 1. factors. A higher K-factor results in a calculation of a This value is the one highest higher, less protective dust level. The two K-factors with measurement found in an early 1983 10(-6) values were for <i person cleaning out a storage study. For most of the measurements, room and fora person vacuum cleaning. asbestos was not even detectable.
1,000 X 0.00001 (10-®) 0.01 Dust level if detection limit of the early This is the K-factor more applicable to a school. This is the detection limit of the study 1983 study is used, and K-factors representing gym aclivities and a person sweeping floors cited. Most of the actual measure air more applicable to a school are used, with a broom levels were below this detection limit
100 X 0.000001 (10-®) 0.0001 Dust level if air concentration is urban This is STILL the inappropriate K-factor chosen by Region Outside ambient air level, urban areas. level cited by the CDC's ATSDR, but 1 for their calculations found credible by the CDC's ATSDR still using the inappropriate K-factor.
10 X 0.000001 ( 10-®) 0.00001 Dust level if air concentration is rural This Is STILL the K-faclor chosen by Region 1 for their Outside ambient air level, rural areas, level cited by the CDC's ATSDR, but calculations found credible by the CDC's ATSDR still using the inappropriate K-factor.
10 X 0.00001 (10-’) 0.0001 Dust level if K-factors more relevant This is the K-factor more applicable to a school. Outside ambient air level, urban air, to school used, and A TSDR value for representing gym aclivities and a person sweeping floors found by the CDC's ATSDR urban outdoor air used. with a broom
1 X 0.00001 (10-®) 0.00001 Dust level if K-factors more relevant This is the K-factor more applicable to a school, Outside ambient air level, rural areas, to school used, and ATSDR value for representing gym activities and a person sweeping floors found by the CDC's ATSDR rural outdoor air used. with a broom
1 X 0.0001 ( 10-*) 0.0001 Dust level if average of the six K- Average of six different K-factors in study, allowing Outside ambient air level, urban air, factors used, and ATSDR value for for a safety margin of error found by the CDC's ATSDR urban outdoor air used.
0.1 X 0.0001 (10-*) 0.00001 Dust level if average of the six K- Average of six different K-factors in study, allowing Outside ambient airlevel, urban areas, factors used, and ATSDR value for for a safety margin of error found by the CDC's ATSDR rural outdoor air used.
■■ 17-
CITY_21MC100_002847473
NYC-WTC_000209443
OCR can misread numbers and units. Confirm readings against the page image before using them.
Related records
Browse subjects →Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
Same-box records
Filed elsewhere
NYC-WTC_000140040
Technical memorandum from EPA discussing ultrasonication testing for asbestos in carpets and HEPA vacuuming effectiveness.
15 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140083
Forwarded EPA memorandum dated June 9, 2002, concerning the Asbestos Reservoir and carpet testing methods.
15 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140138
EPA memorandum addressing World Trade Center asbestos contamination status and agency efforts to provide information on the situation.
13 shared non-person entities · 1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140170
EPA memorandum on wipe sampling methods for asbestos in Lower Manhattan buildings, resuspension projections, and cancer risk estimates from WTC dust exposure.
13 shared non-person entities · 1 shared topics · similarity 0.983
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140127
Technical memorandum from EPA discussing ultrasonication testing for asbestos in carpets and HEPA vacuuming effectiveness.
10 shared non-person entities · 1 shared topics · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000151635
EPA memorandum detailing plans for asbestos wipe sampling, projecting airborne dust levels, and estimating increased cancer risks from WTC dust exposure.
11 shared non-person entities · 1 shared topics · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140259
Memorandum detailing procedures for asbestos wipe sampling in Lower Manhattan and estimating associated cancer risks from dust exposure.
11 shared non-person entities · 1 shared topics · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000154652
Internal tracking document for managing reports, comments, and actions related to environmental compliance cases.
11 shared non-person entities · 1 shared topics · similarity 0.977
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140235
Memorandum comparing asbestos data in Manhattan to other sites and arguing for cleanup under the Superfund statute.
11 shared non-person entities · 1 shared topics · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000125845
Draft fact sheet from DOH and DEP addressing tenant concerns regarding asbestos fibers at 105 Duane Street.
11 shared non-person entities · 1 shared topics · similarity 0.960
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000094469
Letter from Enviroscience Consultants providing air and bulk sampling results for 86 Trinity Place.
5 shared non-person entities · 1 shared topics · similarity 0.952
machine-extracted · confidence unavailable · Check page ↗More like this page
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Similarity score 0.930 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.922 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.920 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000176160
Draft assessment summarizing eight months of monitoring data regarding air, dust, and water contaminants at the WTC site and surrounding areas.
Similarity score 0.919 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000178091
Sampling protocol developed to assess residential exposure to airborne and settled dust near the World Trade Center.
Similarity score 0.919 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.918 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Others also read
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000140040
Technical memorandum from EPA discussing ultrasonication testing for asbestos in carpets and HEPA vacuuming effectiveness.
Similar indexed content
NYC-WTC_000140083
Forwarded EPA memorandum dated June 9, 2002, concerning the Asbestos Reservoir and carpet testing methods.
Similar indexed content
NYC-WTC_000140138
EPA memorandum addressing World Trade Center asbestos contamination status and agency efforts to provide information on the situation.
Similar indexed content
NYC-WTC_000140170
EPA memorandum on wipe sampling methods for asbestos in Lower Manhattan buildings, resuspension projections, and cancer risk estimates from WTC dust exposure.
Similar indexed content
NYC-WTC_000140127
Technical memorandum from EPA discussing ultrasonication testing for asbestos in carpets and HEPA vacuuming effectiveness.
Similar indexed content