05/24/2002 12:57 FAI 212 353 8306 ATC 121003

104 East 25ih SI.. 10th Root New York N?w Vort 10010 w/ww.atc- envir6.com

ASSOCIATES ■ INC. 212.353.8200 Fax 212.353.8306

May 24,2002

Mr. Bernard P, Orlan Director, Environmental Health & Safety New York City Board of Education 28-11 Queens Plaza North Long Island City, NY 11101-4008

Re: Wipe Samples for Polychlorinated Biphenyls P. S. 65Q Ozone Park, New York ATC Project No. 15-19125-0334

Dcir Mr. Ortan;

ATC Associates Inc (ATC) is pleased to provide this report of the results of the wipe samples for polychlorinated biphenyls (PCBs) collected on May 17,2002, at the referenced location. The New York City Board of Education (BOE) requested these samples to evaluate possible contamination in the school building.

SCOPE OF WORK

The samples were collected using sterile gauze pads and hexane as a solvent. The samples were analyzed by PSC Analytical Services, Tnc. (PSC), an American Industrial Hygiene Association- accredited laboratory in Reading, PA. The analysis was performed using EPA Method 8082B.

Wagdi Abdelshahid, Industrial I-lygicniSt of ATC’s New York City office, collected the samples consistent with generally accepted industrial hygiene practices. The results of the sampling represent conditions found on the dates the samples were collected.

Results ATC submitted twenty-two samples (including one blank) to PSC for analysis. A copy of die analytical laboratory rqjort is provided in the attadmient. The sample area for each sample was 100 square centimeters (lOOcm^). The twcnty-one areas sampled were;

• HVAC 2 - Surface by the intake; ♦ HVAC 3 - Surface by the intake; • HVAC 5 - Surface by intake; • Room 14 - Desk; • Room 28-Floor; • Room 3fi - Wall; • Room 23 - Tabic; • Room 29 - Vent opening;

CITY_21MC1OO_OO3O164O5 NYC-WTC_000207781

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000207781Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000177930

Report providing wipe sample results for polychlorinated biphenyls (PCBs) collected at P.S. 234M in January 2002.

Similar indexed content

Compare copies and versions →