NYC 9/11 Public Portal Document
I21003
09/14/01 FRI 14:18 FAX 518 485 8449 ENV. CON. POLICE
SEP-14-2001 14:07 USEPA-RESP. 8. PREV. BR. 732 321 4425 P.02/03
USEPA Air Analytical Results from 9/13/01 Sampling Eyent
26 Federal Plaza: Seven air samples were collected at the 26 federal Plaza (I3'\ 26th,38th,39th
floor and in the lobby). The asbestos concentrations ranged from non-detect to 0.0072 fibers/cc
(south lobby). Dara results are less than the OSHA Permissible Exposure Limit of 0.1 fibers/cc.
290 Broadway; Six air samples were collected at the 290 Broadway (8‘'', 22th, LL-1, LL-2 and
Lobby). The asbestos concentrations ranged from non-detect to 0,0133 fibers/cc (LL-1).
One Chase Plaza: One outdoor air sample was collected at the one chase plaza; the asbestos
concentration was 0.0098 fibers/cc.
Methodology
Air samples were analyzed by TEM EPA 40CFR763 AHERA.
Dust samples were analyzed by PLM - EPA-600 R-93/116.
CITY_21MC100_0 08993086