HEALTH sr SAFETY SERVICES, INC. PO Box 249 • Hammonton, NJ 08037 • (609) 704-8850 • Fax (609) 561-7646

Indoor Air Quality • Asbestos Sr Lead Management • Site Assessments

January 6, 2002

Mr. Wayne Barthel Fleet Manager GSA Fleet Management 2890 Woodbridge Avenue Building 201 Edison, New Jersey 08837

Re: Automobile Asbestos Contamination Investigation Vehicle Tag # 01345

Dear Mr. Barthel:

Per your request. Health & Safety Services, Inc. provided the services of an EPA7AHERA Licensed Asbestos Building Inspector to determine the extent of contamination of a car that has been subject to suspect asbestos containing debris.

Two types of samples were collected from the automobile:

A bulk sample was collected from under the hood of the car adjacent to the cowl. The sample was collected using 40 CFR 763 protocols and were analyzed utilizing Polarized Light Microscopy techniques by NVLAP approved laboratories. Upon analysis of the sample, asbestos was detected above the regulatory limit of I % by weight.

A Transmission Electron Microscopy Microvacuum Dust sample was collected from the back seat of the car. The sample was collected using a 25-mm diameter MCE filter contained in a three- piece standard TEM AHERA air cassette with a one inch piece of tubing attached to the face cap as a nozzle. The end of the nozzle is cut at a 45° angle. The cassette is connected to a personal sampling pump with flexible tubing and calibrated at 2 liters per minute. The area to be sampled is then vacuumed for 2 minutes, or until there is no visible dust remaining in the sampling area. At the end of sampling, the cassette is turned upward before shutting off the power to the pump. The nozzle is plugged and the cassette end sealed with an end plug. The assembly is appropriately packaged to prevent separation of the nozzle from the cassette and sealed in a plastic bag. The sample was analyzed for the presence of asbestos with the use of a Transmission Electron Microscope. Asbestos was detected and the type is consistent with the material found under the hood of the car.

(ISA Meet .Management ( chicle # 01345

CITY_21MC100_009131922

NYC-WTC_000188027

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000188027Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →