Asbestos inspection report, 130 Liberty Street, Oct 2008

Machine-extracted title · confidence 95%

Inspection record documenting an asbestos inspection at 130 Liberty Street conducted on October 13, 2008.

NYC-WTC_000181905
Page image
Scanned page image, NYC-WTC_000181905
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Asbestos Inspection Report

Premise No. Inspection Date: 130 Liberty Street 10/13/08 Floor Zip Borough Block Lot Squad # Badge # Various 10006 1 54 1 1 AO61 Inspector Building Type Basis of inspection Photos Taken H. Guirguis A TRU0086MN08 Yes Contractor's Name Sample Number LVI Environmental Address City Sample Number

State Zip Phone Sample Number

Laboratory Name Owner’s Name TRC Environmental Corp The Lower Manhattan Development Corp. Address City Address City 1430 Broadway New York One Liberty Plaza New York State Zip Phone State Zip Phone NY 10018 NY 10006 (212) 962-2300 Contact Person Time of Inspection from: Arnel Javal, Sr. Proj. Mgr./TRC Environmental 05:00pm - 06:30pm

On arrival I met Nugent Gerald, Supervisor for LVI Environmental at the LVI field office, who Informed me that a total of 1 Handler Supervisor and 18 Asbestos Handlers were on the 8"’ floor today for the second shift. The daily work schedule informed me of the following:

1. 19"’ floor: 8 men - cut & wrap raceways 2. io’" floors: 16 men (each)- scrap fireproofing, boxing debris, cut raceways 3. 8"' ,7"' & 6"' floors: 18 men (each)- demo, boxing debris 4. Various floors :12 men loading out boxes to ATC trailer

After signing the log book donned personal protection I' entered the work areas.

1. 8"' floor: workers were found in the process of Demo, boxing debris; there was still a lot of wet debris on the floor, demolition was not completed, workers were cutting metals using power tools, HEPA vacuum attached with the power tools, fine spraying amended water in the work area, preparing Gaylord boxes and wrapping beams, HVAC ducts and cabinets, Gaylord boxes and numerous poly wrapped beams were at various locations on the floor ready to be taken out, Inspection was done on the Micro trap Machines and the Micro trap tents and on all the work area.

2. g'" floor thru 6"’ floor: There was no activity or personnel observed on the floor Inspection was done on the Micro trap machines and the Micro trap tents and on all the work area.

I used the stairs to go back to the 8"' floor.

I exited the work area after decontaminating myself and signing the log book

NOV# Infraction Infraction Infraction Infraction

NOV# Infraction Infraction Infraction Result Code 2 NOV# Infraction Infraction Infraction Supervisor^nitial

Borough 1 “Manhattan 2=Bronx 3=Brooklyn 4=Queens 5=Richmond Building Type A >6 stories B <6 stories C single family D school E hospital F public owned Result Code I = Violation Issued 2“No Violation Issued 3“No access 4=Project not started (no NOV) 5=Public Owned Property

CITY_DEP_WORBY_CANNATA_SUBP_000130497

NYC-WTC_000181905

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000181905Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →