NYC 9/11 Public Portal Document SUBJECT TO PROTECTIVE ORDER NO. SEPT. 2008 CONFIDENTIAL, CITY_21MC100. 003464226 NYC-WTC_000180206 ATC ASSOCIATES, INC. Page 1of _14_ INDOOR AIR QUALITY FIELD REPORT Time: 8.25Am LOCATION: 90 Trinity Place /HS for Leadership and public services DATE: 5,8/02_PROJECT NO: 15-19125-0290 Temperature (F) Humidity (%) (ppm) (ppm) s (ug/m) Out Doors MAIN ENTRANCE 68 •0 49.3 403 57 0-0 Out Doors NORTA OF MAIN ENTRANKE 68.0 49.6 416 43 0•0 Out Doors SOUTA OFMAIN ENTRANeE 685 49.8 435 54 0.0 LOBBY /St FlUOR 10 125 51-8 466 22 0.0 CLEVATOR LOBBY FROOR 20 73.5 51•4 468 12 0 0 1415 flooR Hallway 4 25.1 50.6 558 10 0.0 1419 flooR JATUtEN 2 76.5 50.5 502 14 0.7 141KFLO0R ROOm #1406 FuLl FuLL 76.1 49.5 579 6 10 0.0 STAIR CASE À'TO1SHE 2 166 49.4 557 8 0.0 Room# 1403 17 76.5 501 654 8 0-8 Guideline levels 68-75F/winter ASHRAE/ATHA 30-60% Outdoor level 9ppm 65 ug/m 1 ppm 73-79 E/summer +700 ppm Comments: The assessed location(s) () Does () Does not meet established indoor air quality guidelines. signature: fr zaden Date: 5/8/02

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000180206Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000180169

ATC Associates indoor air quality field report for 90 Trinity Place detailing temperature, humidity, and pollutant levels in March 2002.

Similar indexed content

NYC-WTC_000180049

Field report containing indoor air quality data for 100 Trinity Place collected in May 2002.

Similar indexed content

NYC-WTC_000180033

Field report form documenting indoor air quality measurements taken at a school in May 2002.

Similar indexed content

Compare copies and versions →