Indoor Air Quality Field Report, 90 Trinity Place, Mar 2002

Machine-extracted title · confidence 95%

ATC Associates indoor air quality field report for 90 Trinity Place detailing temperature, humidity, and pollutant levels in March 2002.

NYC-WTC_000180169–000180182
Page image
Scanned page image, NYC-WTC_000180169
OCR text

OCR status: ocr · source: ours

NYC 9/11 Public Portal Document SUBJECT IO PROTECTIVE ORDER NO. CONFIDENTIAL, SEPI. 2008 CITY_21MC100. _003463590 NYC-WTC_000180169 ATC ASSOCIATES, INC. INDOOR AIR QUALITY FIELD REPORT Time: 10.40A7 UEADERSHIP PUBLCSERUIES LOCATION: 90 Trinity Place /HS for Eeonomies And Finances DATE: 03/08/2002 Location Occupants Temperature (*F) Relative Carbon Humidity: Dioxide (%) (ppm) OUTSIDE MAIN ENTRANE 51.5 412 389 NORTH OF MAI ENTRANCE 480 473 384 SOUTH OF MA IN ENTRANCE 50.6 497 413 4HFloOR Hall wal •LEVATOR AREI 2 66.1 44.8 584 14th flooR KITCHEN 3 67.1 42:3 617 4ItFLOOR CAFETERIA Room # 140 15 67-6 415 963 STAIRWEL A 14th FWOR TO I3Hti FlUOR. 2 67:9 388 635 13Ht EEvATOR ilUay 68.2 37-1 571 I3tt Plook Room #1306 20 68.1 373 541 131t FlUOR ROOM#|303 67.9. 361 525 Guideline levels ASHRAE/AIHA 68-75°F/winter 30-60% Outdoor level 73-78.5°F/summer +700 ppm Page 1 of 14 Comments: PROJECT NO: 15-19125-0290 Carbon Monoxide (ppm)~ 4 3 Respirable TVOCS Particulate (ppm) s(up/m) 125 119 138 45. 44 2 46. 2 2 44 45° 2 2 9 ppm 60 C 38 50 ug/m" 1 ppm The assessed location(s) () Does () Does not meet established indoor air quality guidelines. Signature: Prasad Doddapanenil Prased Doddapaer Date: 03/08/02

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000180169Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000180206

ATC Associates indoor air quality field report for 90 Trinity Place documenting environmental conditions in May 2002.

Similar indexed content

NYC-WTC_000180049

Field report containing indoor air quality data for 100 Trinity Place collected in May 2002.

Similar indexed content

NYC-WTC_000180033

Field report form documenting indoor air quality measurements taken at a school in May 2002.

Similar indexed content

NYC-WTC_000180023

Field report containing indoor air quality data for 100 Trinity Place collected in May 2002.

Similar indexed content

Compare copies and versions →