Indoor Air Quality Field Report, May 2002, 100 Trinity Place

Machine-extracted title · confidence 95%

Field report containing indoor air quality data for 100 Trinity Place collected in May 2002.

NYC-WTC_000180061–000180069
Page image
Scanned page image, NYC-WTC_000180067
OCR text

OCR status: ocr · source: ours

NYC 9/11 Public Portal Document SUBJECT TO PROTECTIVE ORDER NO. SEPT. 2008 CONFIDENTIAL, ATC ASSOCIATES, INC. Page 1_of 10 Time: 3.05pm INDOOR AIR QUALITY FIELD REPORT LOCATION: 100 Trinity Place /HS for Economics And Finances DATE: 52(02PROJECTNO: 15-19125-0291 Location. Occupents, Temperature (F" Relatye- Carbon Carbonae Respirablen Humidity Dioxide Monoxide Particulate (%) (ppm) (ppm) k ‹TVOCs (Ppm) (ug/m) đr Room+ 915 Roan + 910 Roar + 909 Room# 913 Roau#922 Roaut 933 Roan+ 904 Roavt 905 Roont 906 STAIRWEL'À'TO 8'K400R Guideline levels ASHRAE/AIHA 741 29.1 1069 5 13:8 263 875 2 13.7 260 826 13.9 25% 239 24.2 109 0 74'3 24.2 735 12 2 5 3 14.5 235 680 14•4 232 691 00 0•0 00 0-0 0.0 0 0 0 •0 14.2 231 101 74.2 25.5 68 - 75°F/winter 30-60% 158 Outdoor level 9 ppm 2 5 7 65 hg/m 0•0 1 ppm 73-79 "F/summer +700ppm Comments: The assessed iocation(s) () Does () Does not meet established indoor air quality guidelines. Signature: Date5/ 20/02 CITY_ 21MC100 003462628 NYC-WTC_000180067

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000180067Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000180005

Field report containing indoor air quality data for 100 Trinity Place collected on May 8, 2002.

Similar indexed content

NYC-WTC_000180049

Field report containing indoor air quality data for 100 Trinity Place collected in May 2002.

Similar indexed content

NYC-WTC_000180023

Field report containing indoor air quality data for 100 Trinity Place collected in May 2002.

Similar indexed content

NYC-WTC_000180033

Field report form documenting indoor air quality measurements taken at a school in May 2002.

Similar indexed content

Compare copies and versions →