Indoor Air Quality Field Report, May 2002, 100 Trinity Place

Machine-extracted title · confidence 95%

Field report containing indoor air quality data for 100 Trinity Place collected in May 2002.

NYC-WTC_000180061–000180069
Page image
Scanned page image, NYC-WTC_000180068
OCR text

OCR status: ocr · source: ours

NYC 9/11 Public Portal Document SUBJECT IO PROTECTIVE ORDER NO. SEPT. 2008 CONFIDENTIAL, ATC ASSOCIATES, INC. Page 8 of_10_ Time: 308pm INDOOR AIR QUALITY FIELD REPORT LOCATION: 100 Trinity Place /HS for Economics And Finances DATE:&2002PROJECTNO: 15-19125-0291 aLocation Occupans Tempersrg CP Rdaue eCarbon Carbon* Respirable TYOCS umidits Dioxide Monoxide (ppm) Tarficulate ((ppm) (ppm)'© CAFETERIA 50g/m) 130 257 854 1° 0•0 Roana 707 12 14.6 286 958 Roau= 705 25.0 288 999 0.0 Roan+ 704 76.1 28.6 968 0-0 Roan+ 703 261 282 910 0.0 STAIRWEU'A' TO floot 76.4 27:8 102) 15 00 Roout 606 full Roaux 60฿ 5 22.1 309 1155 5 0•0 78.0 328 1169 0.0 Rou+608 FULL 78.3 Room # 604 5 30•0 1152 0.0 Guideline levels 29.0 299 1255 4 0•0 68 - 75°F/winter ASHRAE/AIHA 73-79 °F/summer 30-60% Outdoor level 9 ppm 65 ug/m" 1 ppm + 700 ppm CITY_21MC100_003462629 NYC-WTC_000180068 Comments: The assessed iocation(s) () Does () Does not meet estabiished indoor air quality guidelines. Signature: Date: S/20/01

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000180068Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000180005

Field report containing indoor air quality data for 100 Trinity Place collected on May 8, 2002.

Similar indexed content

NYC-WTC_000180049

Field report containing indoor air quality data for 100 Trinity Place collected in May 2002.

Similar indexed content

NYC-WTC_000180023

Field report containing indoor air quality data for 100 Trinity Place collected in May 2002.

Similar indexed content

NYC-WTC_000180033

Field report form documenting indoor air quality measurements taken at a school in May 2002.

Similar indexed content

Compare copies and versions →