Air monitoring report, WTC site, undated

Machine-extracted title · confidence 85%

KAM Consultants report on phase contrast microscopy analysis of air filters submitted to Citywide Administrative Services.

NYC-WTC_000178268–000178272
Page image
Scanned page image, NYC-WTC_000178269
OCR text

OCR status: ok · source: pdftotext

z KAM CONSULTANTS Z

s 35-40 36th Street Long island City REPORT OF AIR MONITORING o co

New York ,11106 {PHASE CONTRAST MICROSCOPY ANALYSIS OF AIR FILTERS) fl ■a Tel: (718)729-1997 c CT o o Fax: (718)729-1876 CLIENT: DCAS DATE: 09/27/01 o' PROJECT: ADDRESS; 125 Worth Street, Manhattan ■a o 00 10th, Sth, 6th. 4th, 2nd,& 1st Floor 3. ro =^===: 03 CD R W co CLIENT FLOW FLOW SAMPLE FIBERS FIBERS o E O TIME TIME SAMPLE LOCATION BEF. AFTER VOLUME PER PER REMARKS LAB ID# o S R IN OUT o ID# (Ipm) (Ipm) (liters) FIELD CC c P K 3 01 10th Floor - Stairs A. Exit CD 10:45 12:45 10 10 1200 <0.055 <0.01 Air Quality (Immed. TAT) A010928H-01 02 10th Floor - Stairs B Exit & Elevator Lobby_______ 10:46 12:46 10 10 1200 0.065 <0.01 Air Quality (Immed. TAT) A010928H-02 03 10th Floor - Stairs C Exit & Elevaor Lobby 10:47 12:47 10 10 1200 <0.055 <0.01 Air Quality (Immed. TAT) A010928H-03 04 10th Floor - Stairs D Exit 10:48 12:48 10 10 1200 <0.055 <0.01 Air Quality (Immed. TAT) A010928H-04 05 8th Floor - Stairs A Exit 11:09 13:09 10 10 1200 <0.055 <0.01 Air Quality (Immed. TAT) A010928H-05 06 Sth Floor - Stairs B Exit & Elevator Lobby________ 11:10 13:10 10 10. 1200 <0.055 <0.01 Air Quality (Immed. TAT) A010928H-06 07 Sth Floor - Stairs C Exit 11:11 13:11 10 10 1200 0.070 <0.01 Air Quality (Immed. TAT) A010928H-07 08 Sth Floor - Stairs D Exit 11:12 13:12 10 10 1200 <0.055 <0.01 Air Quality (Immed. TAT) A010928H-08 09 Sth Floor - Stairs A Exit 11:25 13:25 10 10 1200 <0.055! <0.01 Air Quality (Immed. TAT) A010928H-09 10 Sth Floor - Stairs B Exit & Elevator Lobby________ 11:26 13:26 10 10 1200 0.055 <0.01 Air Quality (Immed. TAT) A010928H-10 11 Sth "loor - Stairs C Exit 11:27 13:27 10 10 1200 <0.055 <0.01 Air Quality (Immed. TAT) A010928H-11 12 Sth. Floor - Stairs b Exit 11:28 13:28 10 10 1200 "^DO^ <0.01 Air Quality (Immed. TAT) A010928H-12 13 4th Floor - Stairs A Exit 11:50 13:50 10 10 1200 <0.055 <0.01 Air Quality (Immed. TAT) A010928H-13 14 4th Floor - Stairs B Exit & Elevator Lobby________ 11:51 13:51 10 10 1200 <0.055 <0.01 Air Quality (Immed. TAT) A010928H-14 15 4th Floor - Stairs C Exit 11:52 13:52 10 10 1200 <0.055 <001 Air Quality (Immed. TAT) A01Q928H-15 16 4th Floor - Stairs D Exit 11:53 13:53 10 10 1200 <0.055 <0.01 Air Quality (Immed. TAT) A010928H-16 17 2nd Floor - Stairs A Exit 12:10 14:10 10 10 1200 <0.055 <0.01 Air Quality (Immed. TAT) A010928H-17 18 2nd Floor - Stairs B Exit & Elevator Lobby 12:11 14:11 10 10 1200 <0.055 <0.01 Air Quality (Immed. TAT) A010928H-18 '19 2nd Floor - Stairs C Exit 12:12 14:12 10 10 1200 0.065 <0.01 Air Quality (Immed. TAT) A010928H-19 20 2nd Floor - Stairs D Exit 12:13 14:13 10 10 1200 <0.055 <0.01 Air Quality (Immed. TAT) A010928H-20 21 1st Floor Lobbies - Main Entrance 125 Worth Street 12:30 14:30 10 10 1200 <0.055 <0.01 Air Quality (Immed. TAT) A010928H-21 22 1 st Floor Lobbies - West Entrance Lafayette Street 12:31 14:31 10 10 1200 <0.055 <0.01 Air Quality (Immed. TAT) A010928H-22 23 1st Floor Lobbies - Middle of Main Lobby 12:33 14:33 10 10 1200 <0.055 <0.01 Air Quality (Immed. TAT) A010928H-23

TYPE OF RESPIRATORS: 1 = HALF FACE, 2 = PAPR, 3 = TYPE C, 4 = OTHER (SPECIFY); TYPE OF WORK: 1= BLDG DECON, 2 = PLASTICIZING, 3 = GROSS REMOVAL, 4 = GLOVEBAG, 5 = CLEANING, 6 = ENCAPSULATION, 7 = BAGOUT, 8 = OTHER (SPECIFY): o SAMPLING TECHNICIAN: M. Golembo, M. Tchatchueng, Z.B. Nowak DATE RECEIVED: 09/28/01

fl H K ROTAMETER: KAM- 04 DATE OF ANALYSIS: 09/28/01 I DATE OF REPORT: 10/01/01 N3 Analyst: Lab Manager: S O D^pak'Bajracharya David Chen o The samples listed above are analyzed by Phase Contrast Microscopy (PCM) as per NIOSH 7400 Method -Issue 3. The detection limit of this method is 7 fibers per square mm per filter area. o KAM CONSULTANTS shall not be liable for information arising from samples that are not in its QA and QC program. I o The results relate only to the i'ems calibrated or tested. The certificate of report shall not be reproduced without approval of the laboratory. The report must not be used by the client to claim endorsement by NVLAP or any agency of the U.S. Government. co co Nys-DOH ELAP # ! >273 AIHA # IM269 1 to os

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000178269Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000178237

Document header identifying the project and laboratory performing phase contrast microscopy analysis of air filters for DCAS.

Similar indexed content

NYC-WTC_000178204

Document header identifying the project and laboratory performing phase contrast microscopy analysis of air filters for DCAS.

Similar indexed content

NYC-WTC_000178241

Document header identifying the project and laboratory performing phase contrast microscopy analysis of air filters for DCAS.

Similar indexed content

NYC-WTC_000178222

Document header identifying the project and laboratory performing phase contrast microscopy analysis of air filters for DCAS.

Similar indexed content

NYC-WTC_000178231

Document header identifying the project and laboratory performing phase contrast microscopy analysis of air filters for DCAS.

Similar indexed content

Compare copies and versions →