NYC 9/11 Public Portal Document
Pace Analytical Services, Inc.
1700 Elm Street - Suite 200
Minneapolis, MN 55414
TM
'ace Analytical__________ Method 8290 Analysis Results
Tel; 612-607-1700
Fax- 612- 607-6444
Client - ATC
Client's Sample ID ATC-0315-234M-DX1
Lab Sample ID 103399192
Filename U20405B_11
Injected By CVS
Total Amount Extracted 1 m2 Matrix WIPE
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 03/15/2002
ICAL Date 03/25/2002 Received 03/19/2002
CCal Filename(s) U20405A_16 & U20405B_16 Extracted 04/01/2002
Method Blank ID BLANK-1546 Analyzed 04/06/2002 07:31
Native Cone EMPC LRL Internal ng's Percent
Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2,3,7,8-TCDF —- 0.0037 0.0053 lA 2,3.7,8-TCDF-13C 2.00 59
Total TCDF 0.035 —- 0.0020 2,3,7,8-TCDD-13C 2.00 54
1,2,3,7,8-PeCDF-13C 2.00 64
2,3,7.8-TCDD ND 0.0051 A 2,3,4,7,8-PeCDF-13C 2.00 70
Total TCDD 0.077 0.0020 1,2,3,7,8-PeCDD-13C 2.00 68
1,2,3,4,7,8-HxCDF-13C 2.00 65
1,2,3,7.8-PeCDF ND 0.0100 1,2,3,6,7,8-HxCDF-13C 2.00 68
2,3,4,7,8-PeCDF ND 0.0100 2,3,4,6,7,8-HxCDF-13C 2.00 65
Total PeCDF 0.010 0.0100 J 1,2,3,7,8,9'HxCDF-13C 2.00 59
1.2,3,4,7,8-HxCDD-13C 2.00 72
1,2,3,7,8-PeCDD ND 0.0100 1,2,3,6,7,8-HxCDD-13C 2.00 55
Total PeCDD 0.019 0.0100 J 1,2,3,4,6,7,8-HpCDF-13C 2.00 64
1,2,3,4,7,8,9-HpCDF-13C 2.00 64
1,2,3,4,7,8-HxCDF ND 0.0100 1,2.3,4,6,7,8-HpCDD-13C 2.00 73
1,2,3,6,7,8-HxCDF ND 0.0100 OCDD-13C 4.00 54
2,3,4,6,7,8-HxCDF ND 0.0100
1,2,3,7,8,9-HxCDF ND 0.0100 1.2,3,4-TCDD-13C 2.00 NA
Total HxCDF ND 0.0100 1,2,3,7,8,9-HxCDD-13C 2.00 NA
1,2,3,4,7,8-HxCDD ND 0.0100 2,3,7,8-TCDD-37CI4 0.20 65
1,2,3,6,7,8-HxCDD ND 0.0100
1,2,3,7,8,9-HxCDD ND 0.0100
Total HxCDD ND 0.0100
1,2,3,4,6,7,8-HpCDF 0.010 0.0100 J Total 2,3,7,8-TCDD
1.2,3,4,7,8,9-HpCDF ND 0.0100 Equivalence: 0.0010 ng/m2
Total HpCDF 0.026 0.0100 J (Using ITE Factors)
1,2,3,4,6,7,8-HpCDD 0.042 0.0100 JA
Total HpCDD 0.092 0.0100
OCDF ND 0.0200
OCDD 0.520 0.0290 A
LRL = Lower Reporting Limit
Cone = Concentration (Totals include 2,3,7,8-substituted isomers) I = Interference
EMPC = Estimated Maximum Possible Concentration E = PCDE Interference
A = Detection Limit based on signal-to-noise measurement S = Saturated signal
J = Concentration detected is below the calibration range ND = Not Detected
B = Less than 10 times higher than method blank level NA = Not Applicable
P = Recovery outside of target range NC = Not Calculated
Nn = Value obtained from additional analysis • = See Discussion
Report No.... 02-1055252
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc.
CONFIDENTIAL, CITY_21MC100_003444394
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000177782