NYC 9/11 Public Portal Document
wrc ASSOCIATES INC.
104 East 25th St
New York, New York 10010
www.atc-enviro.com
212.353.8280
Fax 212.353.8306
February 28, 2002
Mr. Bernard P. Orlan
Director, Environmental Health and Safety
New York City Board of Education
28-11 Queens Plaza North
Long Island City, NY 11101
Re: Air Sampling for Lead
P.S./I.S. 89M
ATC Project No. 15-19125-0297
Dear Mr. Orlan:
ATC Associates, Inc. (ATC) is pleased to provide this report of the results of air samples for lead
collected on February 22, 2002, at the referenced school. The New York City Board of
Education (BOE) requested this sampling to determine ambient air lead concentrations inside and
outside the school.
Scope of Work
ATC collected ten (10) samples for metals at specified locations. Samples were collected for
twelve (12) hours using 37 mm mixed cellulose ester filters connected to electric sampling pumps
at a flow rate of 10 liters per minute. Pumps were calibrated before and after each sampling
period. Seven (7) samples were collected inside the building and three (3) were collected in the
playground (north and south end) and the roof central area. Two (2) blanks sample were also
submitted. The samples were analyzed by ATC’s American Industrial Hygiene Association-
accredited laboratory in New York City. Analysis was performed by NIOSH Method 7082. A
copy of the laboratory report is attached.
The sampling locations v/ere as follows:
• Cafeteria (Northeast quadrant);
• Floor Hallway Outside Cafeteria;
• Playground North End;
• Playground South End;
• 2"^ Floor Auditorium Room 217 rear Walkway;
• 3"* Floor Gym Room 315 -West quadrant near outlet;
• 5* Floor South End Hallway;
• 4* Floor South End Hallway;
• 2"“ Floor South End Hallway;
• Roof - Central Area.
CONFIDENTIAL, CITY_21MC100_003423054
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000175969