NYC 9/11 Public Portal Document
B;
104 East 25th St., 10th Fl
New York, New York 10010
www.atc-enviro.com
212.353.8280
Fax 212.353.8306
ASSOCIATES INC.
August 30, 2002
Mr. Bernard P. Orlan
Director, Environmental Health and Safety
New York City Board of Education
28-11 Queens Plaza North
Long Island City, NY 11101
Re: Air Sampling for Lead
Intermediate School 306 X
40 West Tremont Avenue
Bronx, New York
ATC Project No. 15-19125-0246
Dear Mr. Orlan:
ATC Associates, Inc. (ATC) is pleased to provide this report of the results of air samples for lead
collected on August 27, 2002, at the referenced school. The New York City Board of Education
(BOE) requested this sampling to determine ambient air lead concentrations inside and outside
the school.
Scope of Work
ATC collected fourteen (14) samples for lead-in-air at specified locations. Samples were
collected for eight (8) hours using 37 mm mixed cellulose ester filters connected to electric
sampling pumps at a flow rate of 2 liters per minute. Pumps were calibrated before and after each
sampling period. Twelve (12) air samples were collected inside and two (2) air samples were
collected outside the building. Two (2) blanks sample were also submitted. The samples were
analyzed by ATC’s American Industrial Hygiene Association-accredited laboratory in New York
City. Analysis was performed by NIOSFI Method 7082. A copy of the laboratory report is
attached.
The sampling locations were as follows;
• D'Floor Lobby (Atrium);
• Auditorium;
• Gymnasium;
• Library;
• Corridor B-2"‘‘Floor HVAC #7;
• Corridor C - 3rd Floor HVAC #12;
• Corridor A - 4th Floor HVAC #11;
• Boy’s Locker Room;
• Girl’s Locker Room;
• Classrooms 561, 411, 322;
• Roof Intake - outside the building;
• Exterior next to the Mam Entrance.
NYC-WTC_000202519