NYC 9/11 Public Portal Document
n
vJ
ATC Environmental, Inc.
; I 104 East 25th Street
New York, New York 10010
ATC Associates Inc. Approved N.Y. State ELAP #10879
104 East 25th Street ACCREDITED NVLAP Lab Code # 1187
New York, NY 10010 Report Date: 09/28/01
ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM)
with Fiber Identification by Selected-Area Electron Diffraction (SA3D) and Energy-Dispersive X-RAY Spectroscopy (EDS)
Method: AHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987-
n .■
■' Sample Identification Analysis Parameters
LuJ
Proj ect/Site40 Rector Street, NY, NY TEM Sample No.: 5575 5 9654
Fj£orsl2&14
Date Received: Q9/28/01 Grid Openings Analyzed:__ 6
■ r--) Project Sample No.:^^ Average Grid Opening: 106.00 um
Air Volume: 1280 liters Total Area Analyzed; Q.0674 mm2
!"'T
Filter Type: MCE 25 mm diam.,- Pore Site: 0.45 um Analytical Sensitivity: 14.8 s/mm2
i.J Effective Area: 385 mm2 0.0045 s/cc
('--1
FIBROUS PARTICULATES ANALYZED
Number Observed CONCENTRATION
Total
Single Matrix Total. Struct. Filter Air
Fibers Bundles Clusters Struct. Struct •=5um StruGt/mm2 Struct/cc ngm/m3
r.I Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Ambiguous 0 0 0 0 0 0 0.0 0 . 0000 0
J
Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0
Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A
No Identification 0 0 0 0 0 0 C. C 0.0000 N/A
Totals (All Structures) 0 0 0.c 0.0000 N/A
The estimated uncertainty of this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED); None detected
Amphibole Asbestos Type; None detected
The Analysis was carried out in accordance with the approved TEM method.
R This laboratory is in compliance with the quality specified for the method.
n Analyzed by: Report Reviewed by;
Roman Peysakhov Michael A. Gorycki, Ph.D.
ri Director of Electron Microscopy
NYC-WTC_000174860