← Document results/7DCAS/Mayor's Office of Emergency Management 7 World Trade Center - 1, 7 & 23rd Floors Change Order #004 REVISED Amb. Job #S57-5175
Document / 5 pages

Revised Change Order #004, 7 World Trade Center, Sept 1998

Machine-extracted title · confidence 95%

Ambassador Construction submits revised change order for electrical and concrete work at 7 World Trade Center.

NYC-WTC_000173445–000173449

Folder label: “Mayor's Office of Emergency Management 7 World Trade Center - 1, 7 & 23rd Floors Change Order #004 REVISED Amb. Job #S57-5175

Page image
Scanned page image, NYC-WTC_000173445
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

AMBASSADOR CONSTRUCTION CO. INC.

0 Mr. Walter Weems Silverstein Properties, Inc. September 1, 1998

7 World Trade Center New York. NY 10048

RE: Mayor’s Office of Emergency Management 7 World Trade Center -1, 7 & 23rd Floors Change Order #004 REVISED Amb.J.QbJL.a5Ld51I5

Dear Mr. Weems:

We are pleased to submit herewith our revised change order #004 for the following work in accordance with the architect’s and engineer’s drawings and specifications marked Bulletin #1 dated 7/24/98 for the sum of ONE HUNDRED EIGHTY THOUSAND EIGHTY SEVEN DOLLARS ($180,087.00):

1. Delete concrete and reinforcing for new oil tank cradle. <$19,380.00> 4

2. New 4" concrete housekeeping pad under oil tank. $1,500.00 l5oO 3. Installation of Graphic annunciator panel see Note #16 Drawing #E1-23 (FBO).

Also include the following: A) Furnish and install wiring from ATS #1 to Graphic panel at 23rd floor 4#14 3/4" conduit. Control wiring from ATS 2 through 9 to generator control panel is already included in our base bid. Additional cabling from ATS 2 through 9 to Graphic panel is being Claimed under this item.

B) Generator switchgear GS-7 to Graphic annunciator. These wires will run in one conduit in 2" conduit (rigid galvanized in Mechanical Room and riser and EMT in open space). 4#14 per each breaker.

C) 500KW generator sets. Maximum number of wires are 6#14. These wires will also run in the same 2" conduit as described Item B.

D) Panel EPH-23. Maximum number of wires are 4#14 per breaker To Graphic annunciator panel. To furnish and install one normally closed auxiliary contact in each switch as per Note #25, Drawing #E3.01.

Fon/vard... 317 MADISON AVENUE. NEW YORK. NY 10017. 212 922 1020. FAX 212 949 9762

NYC-WTC_000173445

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000173445Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Revised Change Order #004 for OEM, September 1998 · Box 7DCAS

NYC-WTC_000173810

Letter from Ambassador Construction submitting revised Change Order #004 for oil tank cradle and housekeeping pad work at the Mayor's Office of Emergency Management.

3 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.999

machine-extracted · confidence unavailable · Check page ↗
Revised Change Order #004, 7 WTC, Sep 1998 · Box 7DCAS

NYC-WTC_000172050

Revised Change Order #004 submitted by Ambassador Construction Co. Inc. for $294,338 regarding work at the Mayor's Office of Emergency Management dated September 11, 1998.

3 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.981

machine-extracted · confidence unavailable · Check page ↗
Revised Change Order #004, Sept 1998 · Box 7DCAS

NYC-WTC_000173309

Letter from Ambassador Construction submitting a revised change order for work at 7 World Trade Center.

3 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.973

machine-extracted · confidence unavailable · Check page ↗

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000172050 · Box 7DCAS

Revised Change Order #004 submitted by Ambassador Construction Co. Inc. for $294,338 regarding work at the Mayor's Office of Emergency Management dated September 11, 1998.

Filed in the same folder

NYC-WTC_000173271 · Box 7DCAS

A revised change order detailing scope changes and costs for the Mayor's Office of Emergency Management renovation project.

Filed in the same folder

NYC-WTC_000173274 · Box 7DCAS

A revised change order detailing scope changes and costs for the Mayor's Office of Emergency Management renovation project.

Filed in the same folder

NYC-WTC_000173458 · Box 7DCAS

Letter submitting a revised Change Order #004 for concrete and electrical work at 7 World Trade Center.

Filed in the same folder

Compare copies and versions →