NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/7DCAS/Mayor's Office of Emergency Management®7 World Trade Center ®New York, NY 23rd Floor
Document / 1 page

Office partition proposal for 7 WTC, May 1998

Machine-extracted title · confidence 95%

Proposal from ACME Architectural Walls dated May 21, 1998 to furnish and install metal and glass partitions at the 7 World Trade Center.

NYC-WTC_000172845

Folder label: “Mayor's Office of Emergency Management®7 World Trade Center ®New York, NY 23rd Floor

Page image
Scanned page image, NYC-WTC_000172845
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

05/21/98 12:15 05/21/98 12:11 NO.060 D01

ACME ARCHITECTURAL WALLS

May 21,1998

Ambassador Construction Co., Inc. Eat# P-19897 RI 317 Madison Avenue New York, NY 10017 Attn; Mr. Jack Klein Re: Mayor’s Office of Emergency Management 7 World Trade Center New York, NY 23rd Floor Gentlemen; We are pleased to confirm our price .to furnish and install Acme ISO modified type metal and glass office partition for the ref :renced job in accordance with Architectural drawing numbers T-1, A-EG-23, A-l-l, A-7-1, A-23-1 through A-23-6. A-48-1, D-O through D-12, all dated May 4.1998.

14/LF 9’-0” Ceil ing high (5) lite glass partition. 2/LF 9’-0” Ceiling high aU steel panel with perforated steel 3/32” holes staggered 5/32” on center. 2 By pass diywjill conditions. 21/LF 9’-0” Ceiling high footage through (5) single and (1) pair door frames. 5 1%” hollow metal 3’-0” x 8’-0” all steel doors. I/Pr. 1%” hollow metal 3’-0”x8’-0” all steel doors. 69/LF 10’-3”± Ceiling high steel, glass and steel partition top & bottom panels to be perforated steel 3/32” holes staggered 5/32” on center, glass to be Amitron thick anti-reflective laminated glass. Lower panel core to be 7/16” thick bullet resistant fiberglass 4.0 Ibs/SF UL listed Level 3, N1J Type 11 lA. 9/LF 10’-3”± Ceiling high footage through (1) single and (1) pair doors. 1 1%” hollow metal multi lite iloor 3’-0’ x 8’-0”. l/Pr. ly^ hollow metal 3’-0”x 8’ 0” all steel doors. 1 Mock up (to become part of ob). 1 Color Acme AW50SM (one 5olor through out).

For the sura of. ,894.00 Tax Exempt

PARTITION TYPE; ACME 150 modified with recessed head and base./ GLASS & GLAZING: !4” clear tempered, unless noted above; cleaning of glass by others. COLOR: ACME standard one color. HARDWARE: By others; except hinges and door stops, ACME standard US26D finish: installed by ACME. j INSTALLATION; During regular working hours. SHOP DRAWINGS: 1st submission 10 working days. TERMS: Net 30 days. DELIVERY: 6 weeks after receipt of approved shop drawings and field measuring. EXCLUSIONS: Elevator/hoist charges, blocking and/or bracing above hung ceiling, walk up of material.

If we are to proceed with this work, pleas© furnish us with your purchase order.

Very truly yoLirs^ Acme Amitectural PZ^cts, Inc.

CORPORATE HEaDOUARTERS- 513 PORTER AVENUE, I RQQIOXM/New YORK 11227-5395 TEL 718-384-7800 PAX; 718-384-1052 manufacturing 8, ENGINEERING; ;!11 LOMBARDY STRE ET. BROOICLYN.Jtena®filEIQ02-S395 TEL: 710-387-5400 FAX: 718-383-0471

NYC-WTC_000172845

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000172845Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →