NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/7DCAS/Security Systems for Conduits®Sensing and Data Fiber Features and Specifications
Document / 10 pages

Fiber optic specifications for 7 World Trade Center, Nov 1998

Machine-extracted title · confidence 95%

Technical specification document for sensing and data fiber features at the 7 World Trade Center facility.

NYC-WTC_000171944–000171953

Folder label: “Security Systems for Conduits®Sensing and Data Fiber Features and Specifications

Page image
Scanned page image, NYC-WTC_000171947
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Nov-lO-98 03:IIP VIKONICS 201 641 7728 P . 04

MAYOR A omci 01 v:mi-rci-ncy manaoiwi-nt CONUUl l SIX’URITY SY.SJhM Sl‘l ( Il K A I KI.N

' u.. ■

l.I General Description 'rhe successful bidder is required to supply and install specialized security equipment and fiber-optic cable in conduits between the 7“' and 23'''^ floor and die 23rd floor and roof radio room. This will involve adding fibercptic sensor cable in each conduit carrying cables utilized by OEM, The number of conduits and length of the Fiberoptic Sensor Cable is to be determined by the bidder. The specified electronic sensor equipment will be supplied and installed in Room 23-50. fhe sensor unit alarm output is to be connected to die alarm monitoring panel in Room 23-50. All efforts are to be coordinated with other disciplines the Architect, and Vikonics. The Material prices includes the cost of Vikonics to inspect and approve the bidder’s efforts, system setup and calibration, and database generation.

12 LocatioH The site is located at Seven World Trade Center and covers the conduit between tire 23'“' floor, part of the 7'*' Poor, and a radio room on the roof.

13 Applicable Specifications

DIAM 50-3 Defense Intelligence Agency Manual

DCID 1/21 Director of Intelligence Directive

National Electrical Code NYC Building Code

VIKONICS INC HIV 1) NiiniiilM 9. I'MS

NYC-WTC_000171947

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000171947Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Security system specification excerpt, May 1998 · Box 7DCAS

NYC-WTC_000173219

Technical specification document detailing end-of-line resistor wiring requirements for the Mayor's Office of Emergency Management security system.

1 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.929

machine-extracted · confidence unavailable · Check page ↗

Filed elsewhere

Fire Service Summary Report, n.d. · Box FDNY

NYC-WTC_000169205

Document summarizing fire service activities or inspections performed at the specified location.

Similar document embedding; no shared entity or topic indexed. · similarity 0.893

machine-extracted · confidence unavailable · Check page ↗

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →