NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/7DCAS/Space Analysis by Unit project #96-1346
Document / 6 pages

Space analysis cover sheet for OEM project 96-1346

Machine-extracted title · confidence 95%

A cover page dated August 1997 for a space design and programming analysis of the Office of Emergency Management at 7 World Trade Center.

NYC-WTC_000168304–000168309

Folder label: “Space Analysis by Unit project #96-1346

Page image
Scanned page image, NYC-WTC_000168306
OCR text

OCR status: ocr · source: ours

NYC-WTC_000168306 DEPT OF GENERAL SERVICES SPACE DESIGN-PROGRAMMING SPACE ANALYSIS BY UNIT PROJECT#: 96-1346 TAGENCY: DIVISION: PROGRAM: UNIT (S) Office of Emergency Management (OEM) CURRENT ADDRESS: 100 Church St, 20th Floor New York, NY SPACE ANALYST: S. Lee Wright IA/Jefferson UNIT PERSONNEL TOTAL INCL Technology "Critical" Areas PERSONNEL w/CIRC. DATE: 8/18/97 COMMON/EQUIP. w/CIRC. PAGE 2 OF UNIT CODE: UNIT GRAND TOTAL 19,142 19,142 CSF ¡All requirements outlined on this page are to be clustered together as part of the "TECHNOLOGY" side of the facility and may be separated from the "OFFICE" suite réquirements as depicted on previous page. Alt requirements outlimed on this page are concidered "Critical Areas" to be operational during ai crisis. COMMON & EQUIPMENT AREAS S.F. TOT. (EOC) Emergency Operations Center(2J Used as Main Operating Room in emergenceis. 90 workstations @ approvximatety 56sf each Each desk to be min. 5' x 3.5' with a computer, tv and phone. Projection screen/projectors/AV equipment Гo be used as a large onference room when necessary Special HVAC, Lighting and secured window TBD Copy Area for room "Specialized consultant to devleop program requirements* (PIU) Public Information Unit/Training Room (Telophone Room) : 1,400| Used as Telephone Hot Line room in emergencies. 70 seats for conference/training style set up @ approx. 20sf eh Raised floor for telephones to be stored when not in use. Projection screen/projectors • Specialized consultant to devleop program requirements* Watch Command / Radio Hardware Room 10 Used as the Radio communications room during emergencies. 10 workstations Acoustical value important to design. Raised fioor for special equipment/Radio Infrastructure 24 hr/day/7 days/wk/365 days/yr operation.. Special HVAC requirements for room to be determined. * Specialized consultant(Motorola) developing program requirements* Rear Screen Projection Room 500 Rear Screen projection Room Adjacent to the EOC room Approximate size 15'x 35' Contains all AV equipment and suppport equipment. COMMON & EQUIPMENT AREAS Agency Conference Room (i 2 Conference rooms for the staff in the EOC room ModernFold adjustable partitions in between ms To house private meeting for NYPD, Fire and other Location for the (3) Commissioners to reside when on site Press Roomi For Live press conferences To house up to 50 reporters @10sf eh Approximate size 25' x 24° Adjacent to the Mayors Suite & EOC room w/ window Raised platform in back for cameras Raised floor for cabling Podium for the speakers Direct "LIVE" line to the street for tv trucks. Large Conferencă Room Adjacent to the Mayors Suite & EOC room To house up to 40 people @25 Sf eh Sound Proof, raised floor Approximate size 35'x 32° Window to the EOC room Staff Kitchen/Lounge Room Main pantry/lounge for staff Pantry to have microwaves and industrial coffee makers Adjacent to Smoking room Vending machinesWATER BOTTLES(5 YR SHELF LIFE) To be near windows, if possible Smoking Room: Soecial ventiallation required OCC. S.F. TOT. 300 COMMON & EQUIPMENT AREAS Bunk Rooms Male/Female @36 SF eh OCC. S.F. TOT. 6 180 800 г 1,000 Changing Rooms Male/Female @ 15SF eh Adjacent to the bunk rooms and showers Shower Rooms For staff during emergencies Male/Female Handicapp accessible Adjacent to changing/bunk rooms Bathroom Sulte for the Mayor Restroom with Shower/changing room and mini pantry Bathroom Suite for the Commissioner Restroom with Shower/changingroom 6 100/ 2 100| BUILDING WINDOWS TO BE SEALED OFF FOR SECURITY: " ÷ EXACT DESIGN TO BE DETERMINED. e3 " Specialized consultant to devleop program requirements* Computer Room (LAN) 500 Main computer equipment room to house all files servers, etc., To be connected to UPS system in lower floor. Approximate size 20'x 25 Special HVAC requirements for room to be determined. Isolated grounding required; separate elec. panel in room Racks to be secured to walls CAT 5 cablino throughout space UPS SYSTEM TO BE ON 23RD FLOOR. Stórage Rooms Communications Equipment Computer Equipment Field Equipment Office Supplies SUB TOTAL SUB TOTAL 360 200 200 250 150 1,160 SUB TOTAL 10.5c0 9/11 Public Portal Document

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000168306Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Space analysis by unit for OEM project 96-1346 · Box 7DCAS

NYC-WTC_000168314

A detailed space analysis sheet dated October 1997 listing personnel counts and square footage for various units at the Office of Emergency Management.

6 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.991

machine-extracted · confidence unavailable · Check page ↗
OEM space analysis summary sheet, Aug 1997 · Box 7DCAS

NYC-WTC_000170916

Space design and programming summary for Office of Emergency Management including personnel counts and square footage.

6 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.990

machine-extracted · confidence unavailable · Check page ↗
Space analysis by unit for OEM project 96-1346 · Box 7DCAS

NYC-WTC_000168320

A detailed space analysis sheet dated October 1997 listing personnel counts and square footage for various units at the Office of Emergency Management.

6 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.988

machine-extracted · confidence unavailable · Check page ↗

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →