Barry L. Hutchinson Design Supervisor / Instrumentation, LifeSafety, &Security Systems
TRIP
Relevant International Monetary Fund, Headquarters Office Building, Washington, DC
Experience/ Architectural, engineering, and interior design and construction administration for this
Qualifications 1,066,000 SF headquarters which houses eating areas, offices, executive suites, business and
(confd.) legal libraries, board rooms, lounges, and conference rooms. Beneath the building is a con
course level housing several service functions and a four-story parking garage
accommodating 800 cars. The Joint Computer Center servicing the needs of the Fund is also
located in the concourse. The 265,000 SF Phase II addition was completed in 1983. Complete
fire alarm system renovation curently underway (800 zones). TKLP is now completing mas
ter site and space planning for a proposed l(X),000 SF computer facility and the Phase III
addition of 410,000 SF.
Sterling Winthrop Inc., Pharmaceuticals Research Division, Upper Providence Township, PA
A complete security analysis and design for this 1300,000 SF pharmaceutical R&D complex.
The project includ^ threat analysis and thorough technical review of security alarm, CCTV,
and manufacturers' card access equipment to determine what was best suited to the project.
Magnetic stripe, proximity, and Weigand card access technologies were considered. In addition
to a complete security communications center, system equipment included 71 CCTV cameras
with fiber optic video transmission, 100 card readers, and remote control of exterior gates.
Guardian Life Insurance Company, Regional Headquarters, Spokane, WA
A/E design, documentation, and construction administration for a three-story 200,0(X) SF
office building to be built in two phases of 100,000 SF each. The design, which includes open
office space, a cafeteria, and a computer room, provides for optimum flexibility in office
planning by including access flooring with modular office partitions and furniture through
out the facilities.
Guardian Life Insurance Company, Regional Headquarters, Appleton,
A./E design, documentation, and construction administration for a three-story 200,000 SF
office building to be built in two phases of 100,000 SF each. The design, which includes open
office space, a cafeteria, and a computer room, provides for optimum flexibility in office
planning by including access flooring with modular office partitions and furniture through
out the facilities.
Exxon Production Research Company, Houston, TX
A 1,100,000 SF complex containing research and development laboratories, administrative
office and training and computer facilities. Responsibilities included engineering a design
of multiplex life safety equipment, card access system, a large multi-camera CCTV system
and an exterior perimeter site microwave system. Data communications for the above sys
tems were engineered using state-of-the-art fiber optic technology due to complex size and
losses normally involved with multiplex and RF transmission using coaxial cable. As with
other projects, Mr. Hutchinson was responsible for original scope development, and for
leading all interdiscipline coordination for HVAC, electrical fire protection and mechanical
design as related to sprinkler, halon and air-handling systems that are interfaced with the
life safety system.
IBM Office Products Division Headquarters, Franklin Lakes, NJ
This project involved a 300,000 SF (Phase II) addition designed for energy conservation. It is
situated so that indirect sunlight reduces artificial light requirements and reduces the amount
of energy needed to maintain the addition. The Phase I building contained a large computer
facility which required an unusually large cooling system. This system was engineered so
that the recovery of the large volume of 105° water could be used to heat the new addition.
Societies American Society for Industrial Security