1 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.908
machine-extracted · confidence unavailable · Check page ↗U.S.S. Intrepid Museum - Pier 86 W. 46 St. DRAWINGS
Label derived from the City's folder field. The City does not supply document titles.NYC-WTC_000165476–000165479
OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Inilependeiii: Tesiing Latoraiories, Inc. Locations In Hew York and New Jersey i'M
129-11 18th AVENUE - COLLEGE POINT. N. Y. 11356 - (212) 961-8530
March 25, 1982;, cx> Client: Morse Diesel Incorporated Co 1133 Avenue of the Americas D New York, New York 10036
Project: Intrepid Museum CTi New York, New YOrk
Subject: Compressive Tests of Concrete Cores.
Location: Sewer Outlet Date Tested: 3/20/82
Core No. 1 2 3 4 Specific Gravity 2.405 2.402 ' 2.407 2.411 Wt./ Cu. Ft. 150.06 149.87 150.20 150.45 Coarse Aggregate CRUSHED STOKE Height Reev’d 8.0 11.5 11.0 • 10.75 Ends Sawed 7.250 7.250 7.250 7.250 Height Capped 7.500 7.500 7.500 7.500 Diameter 3.750 3,750 3.750 3.750 Area (Sq. in.) 11.05 11.05 11.05 11.05 Hght/Dia. Ratio 2.000 2.000 2.000 2.000 Factor 1.000 1.000 1.000 1.000 Load Lbs. 42,500 43,000 42,500 32,000 P.S.I. 3846 3891 3846 2896 Corrected P.S.I. 3846 3891 3846 2896
NYC-WTC_000165477
OCR can misread numbers and units. Confirm readings against the page image before using them.
Related records
Browse subjects →Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
Same-box records
2 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.901
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000165484
March 2, 1982 DEP letter responding to a building structure proposal over an existing sewer outfall at Pier 86.
1 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.901
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000165322
Department of Environmental Protection letter providing design review comments on tunnel project contract drawings, requesting pressure relief manhole details, existing sewer…
2 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.900
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000165853
Contract notes specifying requirements for maintaining existing connections and restoring manholes during tunnel construction.
1 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.898
machine-extracted · confidence unavailable · Check page ↗1 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.898
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000165482
Administrative record listing organizational affiliations or advisory board members from March 1982.
2 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.896
machine-extracted · confidence unavailable · Check page ↗2 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.895
machine-extracted · confidence unavailable · Check page ↗2 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.894
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000165790
Letter provides specific design comments regarding roof slab thickness and removable slab configuration requirements.
1 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.892
machine-extracted · confidence unavailable · Check page ↗Filed elsewhere
NYC-WTC_000137900
Archival folder label for Department of Environmental Protection biweekly reports related to World Trade Center activities from 2000 to 2001.
2 shared non-person entities · 1 shared topics · similarity 0.897
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000143354
Fragmented text containing only a reference number and unreadable characters from the DEP Box 06 collection.
1 shared non-person entities · similarity 0.895
machine-extracted · confidence unavailable · Check page ↗More like this page
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Others also read
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000165461
Single page from DEP records containing only an archive identifier and no other visible content.
Filed in the same folder
NYC-WTC_000165462
Single page from DEP records containing illegible text and an archive identifier related to Pier 86.
Filed in the same folder
NYC-WTC_000165463
Engineering drawings for a project or facility located at Pier 86 on West 46th Street in Manhattan.
Filed in the same folder
NYC-WTC_000165466
Two-page document from DEP records containing largely illegible text and an archive identifier.
Filed in the same folder
NYC-WTC_000165468
Five-page DEP record with largely illegible content related to Pier 86 W. 46th Street drawings.
Filed in the same folder