Foundation Specifications for WTC River Intake Relocation

Machine-extracted title · confidence 95%

Construction specifications document detailing foundation requirements for the World Trade Center river water intake system relocation project.

NYC-WTC_000165112–000165243

Folder label: “WORLD TRADE CENTER - RELOCATION OF RIVER WATER INTAKE LINES & PUMP STATION ELECT. POWER & COMM. LINES

Page image
Scanned page image, NYC-WTC_000165182
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Battery Park City Commercial Center Bldg. ’B* WTC River Water Intake System Relocations

PART II - PRODUCTS ,A. PRESTRESSED CONCRETE CYLINDER PIPE - 20" I.D. LINES 1. The pipe for the relocated auxiliary river water intake lines shall be 20" I.D. prestressed concrete cylinder pipe. 2. Prestressed Concrete Cylinder Pipe shall be of the type known as "Prestressed Concrete Pressure Pipe, Steel Cylinder Type, for Water and Other Liquids”, and shall conform to the latest edition of AWWA Specification C 301. It shall be composed of continuous arc-welded steel cylinder with steel joint rinarj welded to its ends. The steel cylinder shall then be lined with con- Crete, wrapped with high tensile strength wire under tension and coated with a dense covering of cement mor­ tar. 3. The pipe shall be made by a manufacturer experienced in producing pipe of the type, size and quality specified herein. The pipe manufacturer shall have a record of at least five years successful performance in producing this type of pipe. 4. Design: The pipe shall be designed for a working pres­ sure of 22^ p.s.i.g., in combination with the maximum earth load which will be applied after backfill is in place. A surge pressure allowance of of the working pressure, and the applicable live load, shall also be taken into account in the design. The pipe shall with-. stand an internal hydrostatic pressure equal to at least 1.25 times the designed working pressure without induc­ ing tensile stress in the core. a. Pipe shall be furnished in twenty (20) foot nominal lengths, at the option of the manufacturer. b. The steel cylinder shall not be less than 19 gauge. Each completed cylinder shall be subjected to a hydrostatic test, using water pressure sufficient to produce a minimum tensile stress of 20,000 psi in the cylinder walls and shall show no leakage. No cylinders shall be accepted without passing this test.

Pre stressed Concrete Cylinder Pipe 1503C’-2

NYC-WTC_000165182

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000165182Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000165064 · Box DEP Box 44

Request documentation regarding the relocation of river water intake lines and pump station utilities at the World Trade Center.

Filed in the same folder

Compare copies and versions →